background image

1

Quick Start Instructions included 
at the back of this User Guide

EN 50291-1:2018

Fault

Operate

Alarm

Move to

Fresh Air

TEST WEEKLY

 / RESET

Model: 2030-DCR

CARBON MONOXIDE ALARM

Battery Carbon Monoxide Alarm

User and Installer Guide

Model: 2030-DCR

P/N: 2030-7202-01 

2030-7202-01_2030-DCR_UG_54x96_TUV_80%.indd   1

2030-7202-01_2030-DCR_UG_54x96_TUV_80%.indd   1

22-1-7   下午3:17

22-1-7   下午3:17

Summary of Contents for 2030-DCR

Page 1: ...Operate Alarm Move to Fresh Air TEST WEEKLY RESET Model 2030 DCR CARBON MONOXIDE ALARM Battery Carbon Monoxide Alarm User and Installer Guide Model 2030 DCR P N 2030 7202 01 2030 7202 01_2030 DCR_UG_...

Page 2: ...TANT Additional markings can be found on the back of the unit The manufacturer recommends replacing this alarm ten years from the date code on the side of alarm Date Code on side ____________________...

Page 3: ...of CO Alarms 9 6 Recommended Locations for Alarms 11 7 Locations to Avoid 12 8 Installation 13 9 Operation and Testing 14 10 Recognizing Nuisance Alarms 16 11 Battery 17 12 General Carbon Monoxide CO...

Page 4: ...ple In these circumstances the level of indoor CO might actually increase when doors and windows are opened 2 If the alarm continues to sound even after being reset where appropriate then evacuate the...

Page 5: ...a week to verify proper alarm operation CO Alarm Memory unit has experienced a CO alarm event or 100 ppm or more CO within the last 14 days Red LED blinks 1 time every 60 sec None Push button to clea...

Page 6: ...t Amber LED blinks 5 times every 30 sec Chirp every 30 sec See Cleaning Your Alarm section Push test button once to attempt to reset the unit End of Unit Life Amber LED blinks 2 times every 60 sec Two...

Page 7: ...te in the space provided on the side of the alarm A label has been provided that has important information on what to do in case of a CO alarm Place the label at eye level on a wall near the alarm aft...

Page 8: ...t Reset Button Model 2030 DCR Fault Operate Alarm Move to Fresh Air TEST WEEKLY RESET Model 2030 DCR CARBON MONOXIDE ALARM Amber Fault LED 2030 7202 01_2030 DCR_UG_54x96_TUV_80 indd 8 2030 7202 01_203...

Page 9: ...l it has been fixed NEVER IGNORE THE ALARM WARNING THIS PRODUCT IS INTENDED FOR USE IN ORDINARY INDOOR LOCATIONS OF FAMILY LIVING UNITS IT IS NOT DESIGNED TO MEASURE COMPLIANCE WITH COMMERCIAL AND IND...

Page 10: ...r carbon monoxide detection below 50 PPM This alarm requires a continuous supply of electrical power it will not work without power WARNING THIS CARBON MONOXIDE ALARM IS NOT A SUBSTITUTE FOR INSTALLIN...

Page 11: ...window Locate within hearing distance of bedrooms and place at sleeping height if a heating appliance is in the bedroom CO alarms in rooms with sloped ceilings should be located on the high side of t...

Page 12: ...articles may cause nuisance alarm or failure to alarm In insect infested areas Within 300 mm of a light fitting as electronic noise generated by the electronics may cause nuisance alarms Do not instal...

Page 13: ...te When sliding the back plate on the alarm apply pressure to the back plate to ensure that it latches ALWAYS BE CAREFUL TO LOCATE A FREE STANDING ALARM WHERE IT IS UNLIKELY TO BE KNOCKED TO THE FLOOR...

Page 14: ...ion 1 for alarm signal descriptions In high levels of CO the unit will go into alarm in a shorter period of time than at low levels of CO PParts per Million PPM of COof CO TITime until Alarm 50 60 90...

Page 15: ...Audible Indicators table The alarm will sound if the electronic circuitry horn and batteries are working If the alarm does not sound or gives erratic or low volume sound the unit must be replaced WAR...

Page 16: ...CO If the unit re alarms it is sensing high levels of CO which can quickly become a dangerous situation Move to fresh air and call 0800 111 999 WARNING IT IS IMPOSSIBLE TO DETERMINE THE SOURCE OF A CO...

Page 17: ...YOURSELF Low Battery This alarm is equipped with a low battery monitor circuit If the battery capacity is nearing the point where it can no longer provide adequate power for all alarm functions the lo...

Page 18: ...is unit These batteries can be purchased from your local retailer WARNING Alarm will not attach to back plate unless batteries are installed Depleted or removed batteries will render this alarm inoper...

Page 19: ...ted from use of damp proofing materials or other coatings containing alkylalkoxysilanes Potential Sources of CO Wood burning stoves Gas boilers and fires Gas Hobs Oil and coal burning appliances Porta...

Page 20: ...ended for use in ordinary family homes It is not designed to measure compliance with occupational safety and the HSE NOTE Individuals with certain specific medical conditions may need an alarm that op...

Page 21: ...de to fresh air and get emergency help Your first line of defence is an annual inspection and regular maintenance of your appliances Contact a licensed contractor or call your local utility company fo...

Page 22: ...ay lead to a risk of electric shock or prevent it from functioning correctly This action will void your warranty The following substances can affect the CO sensor and may cause false readings and dama...

Page 23: ...lease remove the batteries from the alarm This warranty shall not apply to the alarm if it has been damaged modified abused or altered after the date of pur chase or if it fails to operate due to impr...

Page 24: ...to Fresh Air Fault Operate Alarm Move to Fresh Air TEST WEEKLY RESET TEST WEEKLY RESET Model 2030 DCR Model 2030 DCR CARBON MONOXIDE ALARM CARBON MONOXIDE ALARM 2030 7202 01_2030 DCR_UG_54x96_TUV_80 i...

Page 25: ...T WEEKLY RESET BEEP BEEP BEEP BEEP BEEP BEEP BEEP BEEP BEEP Pause 60 sec Pause 60 sec Pause 60 sec 5 6 Model 2030 DCR Model 2030 DCR CARBON MONOXIDE ALARM CARBON MONOXIDE ALARM 2030 7202 01_2030 DCR_U...

Page 26: ...ade in China EU Authorised Representative Carrier Fire Security B V Kelvinstraat 7 6003 DH Weert NL Kidde Helpline UK 0800 917 0722 Ireland 1800 818 601 Emergency Numbers Gas Emergency Services 0800 1...