Kidde 123/9HI Owner'S Manual Download Page 1

1

Your home is protected with a Kidde Fyrnetics alarm.
Please read through our guide in full. It should be retained for future reference.

Cut out page 6 and pin up near your Consumer Unit/Fuse Box.

Kidde Fyrnetics recommends for maximum protection that both ionisation and
photo-electric (optical) smoke alarms be installed. Ionisation sensing alarms may
detect invisible fire particles (associated with fast flaming fires) sooner than
photoelectric alarms. Photoelectric sensing alarms may detect visible fire particles
(associated with slow smoldering fires) sooner than ionisation alarms. Home fires
develop in different ways and are often unpredictable. For maximum protection,
Kidde recommends that both Ionisation and Photoelectric alarms be installed.Heat
alarms are useful in areas with condensation/dust/high humidity, such as kitchens
and lofts. Heat alarms MUST ALWAYS be interconnected to smoke alarms.

Electrical rating 230V AC,
50Hz 80mA max per alarm
(maximum 80mA for originating unit
with 24 Devices interconnected).

Smoke and Heat alarm

Owner’s Manual

230V Interconnectable Mains Operated Alarms For models:

123/9

HI

, 123/9

HILL

, 323/9

HI

, 323/9

HILL

INSTALLER, PLEASE LEAVE IN SAFE PLACE FOR HOUSEHOLDER

SAVE THIS MANUAL FOR FUTURE REFERENCE

Contents

Section 1.

Alarm Range

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Section 2.

Important Information

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Section 3.

Types of Alarm

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Section 4.

How to Operate/Test the Alarm

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Section 5.

Battery Checking/Changing

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Section 6.

Checking Battery Back-up on Rechargeable/Long Life Models

. . . .8

Section 7.

Maintenance

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Section 8.

What to do in an Emergency

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Section 9.

Troubleshooting

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Section 10.

Useful Hints

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Section 11.

Good Safety Habits

(Cut off Section)

. . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Section 12.

What to do when the Alarm Sounds

(Cut off Section)

. . . . . . . . . . . . .6

Section 13.

Limitation of Smoke/Heat Alarms

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Section 14.

Service and Guarantee

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Kidde Safety Europe, Mathisen Way, Colnbrook, SL3 0HB, UK.

www.kiddefyrnetics.co.uk

© Kidde Fyrnetics 2008

Read this manual thoroughly and follow its instructions regards

regular maintenance. –

it could save your life

.

1235-7222-05

**

*Kite mark is applicable to 100 AND 200 series models.

**Kite mark is applicable to 300 series models.

Lic No: 503753

BS 5446: Pt. 2: 2003

EN14604: 2005

Licence No. KM524754

*

0086-CPD-535595

1235-7222-05_R5.qxd:_  2009.6.10  9:46 AM  Page 1

Summary of Contents for 123/9HI

Page 1: ...oke and Heat alarm Owner s Manual 230V Interconnectable Mains Operated Alarms For models 123 9HI 123 9HILL 323 9HI 323 9HILL INSTALLER PLEASE LEAVE IN SAFE PLACE FOR HOUSEHOLDER SAVE THIS MANUAL FOR FUTURE REFERENCE Contents Section 1 Alarm Range 2 Section 2 Important Information 2 Section 3 Types of Alarm 2 Section 4 How to Operate Test the Alarm 3 Section 5 Battery Checking Changing 4 Section 6 ...

Page 2: ...ion Interconnectable to other Kidde Fyrnetic AC Alarms so all will sound when one is triggered If mains power is lost will operate via battery power if batteries are fresh properly installed Some models use replaceable 9V PP3 type batteries others sealed in rechargeable Long Life batteries BS5839 Pt6 Grade D This type is the minimum grade acceptable on new or materially altered dwellings ENVIRONME...

Page 3: ...se in isolation They will typically go into alarm when the temperature reaches 57 C Suitable for new Building Regulations applicable 1 7 2000 regarding use in kitchens 4 How to Operate Test the Alarm a Operation and L E D Status When your alarm is correctly installed to the mains supply the green L E D light will be on The red L E D will blink about once a minute to indicate the sensor is operatin...

Page 4: ...ush button will hush all but the triggering alarm The triggering alarm is signified by a rapidly flashing red LED For safety reasons the triggering alarm signal can only be silenced by activating the Hush button on the unit Note Dense smoke will override the hush control feature and sound a continuous alarm Caution Before using the alarm hush feature identify the source of the smoke and be certain...

Page 5: ...shown iii Twist alarm as indicated on housing to remove from mounting base plate iv Finally carefully pull off cable harness by squeezing on side to reveal battery compartment Do not touch the pins on back of alarm v Flip up lid and note position of red plastic bar under battery When you remove battery the red door stop bar prevents the door closing unless a battery is reinstalled This prevents th...

Page 6: ... must wake up in order to execute the escape plan Practice allows all occupants to test your plan before an emergency You may not be able to reach your children It is important they know what to do What to do when the Alarm Sounds Alert small children in the home Leave immediately by your escape plan Every second counts so don t waste time getting dressed or picking up valuables In leaving don t o...

Page 7: ... pressing the test button you have a potential emergency Don t panic you will need to think clearly to ensure all family members escape as soon as possible Never stop to collect belongings etc they are replaceable Check the temperature of door handles or doors to check if hot if hot do not open them a fire will be raging the other side of the door Find an alternative escape route Keep doors window...

Page 8: ...heck via Test Button See part 1b above consult a qualified electrician or your Landlord to remedy as soon as possible 10 Useful Hints Smoke heat alarms can only operate correctly if smoke particles heat reach the unit Correct selection siting and installation are covered in the installers manual Building Regulations require new homes to have 1 hard wired smoke alarm per floor and to be interlinked...

Page 9: ... fires Victims can be involved with the fire too old or young or physically or mentally impaired such that they cannot escape even when warned early enough that escape should be possible For these people other strategies such as protection in place or assisted escape or rescue are necessary Smoke alarms cannot provide an alarm if smoke does not reach the unit Therefore smoke alarms may not sense f...

Page 10: ...nance or inadequate AC or DC electrical power or damage caused by failure to abide by the instructions supplied The liability of Kidde Fyrnetics arising from the sale of this alarm or under the terms of this guarantee shall not in any case exceed the cost of replacement of the alarm in no case shall be liable for consequential loss or damaged resulting from the failure of the alarm or for the brea...

Reviews: