IS-DLMG02R-US
We’re here to help
866-558-5706
Hrs: M-F 9am to 5pm EST
Fixture Diagram
Parts List
[A]
Fixture
[B]
Junction Box
[C]
Quick Screw Lock
Connector
[D]
Fixture Cable
Connector
[E]
Junction Box Cable
Connector
[F]
Junction Box Cover
[G]
Strain Relief
Connector
[H]
Push-In Wire
Connectors
[I]
Spring Clips
Installation Instructions
INSTALLATION HOLE SIZES:
DLMG02R fixtures (2" Round fixtures)
DLMG02R SERIES fixtures require a round installation hole at least 2-1/8" (54mm) in
diameter.
1) Disconnect junction box
[B]
from fixture
[A]
by unscrewing quick screw lock
connector
[C]
, then carefully pulling apart fixture cable connector
[D]
from junction
box cable connector
[E]
.
Cautions
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main fusebox before starting and
during the installation.
WARNING:
This fixture is intended for installation in accordance with the National Electrical Code
(NEC) and all local code specifications. If you are not familiar with code requirements,
installation by a certified electrician is recommended.
Supply wires are not intended for use through or concealed behind walls, floors, or
ceilings.
The LED light output is strong enough to injure human eyes. Precautions must be taken
to prevent looking directly at LED’s with unaided eyes for more than a few seconds.
DIMMING:
This LED fixture is compatible with phase cut dimmers only. For listed compatible
dimmers, see www.kichler.com
CLEANING:
• Always be certain that electric current is turned off before cleaning.
• Only a soft damp cloth should be used. Harsh cleaning
products may damage the finish.
1) Read and understand all instructions and illustrations completely before proceeding
with assembly and installation of fixture.
2) If you have any doubts about how to install this fixture, or if the fixture fails to
operate completely, please contact a qualified electrician.
3) All parts must be used as indicated in the instructions. Do not substitute any parts,
leave parts out, or use any parts that are worn or broken. Failure to obey this
instruction could invalidate the UL listing, C.S.A. certification, and/or ETL listing of this
fixture.
4) Fixture is to be connected to a single branch circuit.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1)
This device may not cause harmful interference, and
2)
This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
FCC Information:
For warranty information please visit:
kichler.com/warranty
2) Open junction box cover
[F]
and remove preferred junction box knockout using a
flat-head screwdriver.
3) Pass Romex supply cable through included strain relief connector
[G]
and into
junction box through knockout hole. Secure in place using strain relief connector.
4) Connect ground wire from Romex supply cable to green fixture ground wire using
included push-in wire connector
[H]
.
5) Make the remaining wire connections using included push-in wire connectors.
Reference chart below for correct connections and wire accordingly.
Connect Line
(Black or Red Supply Wire) to:
Connect Neutral
(White Supply Wire) to:
Black
White
*Parallel cord (round & smooth)
*Parallel cord (square & ridged)
Clear without Tracer
Clear with white Tracer
*Note: When parallel wire (SPT 1 & SPT 2) are used. The
neutral wire is square shaped or ridged and the other wire
will be round in shape or smooth (See illus.)
Neutral Wire
6) After wire connections are made, place all wires inside junction box and close cover,
being careful not to pinch any of the wires between the junction box and cover.
7) Raise junction box through installation hole and into the ceiling.
NOTE:
If installing to new construction, mount junction box to a nearby joist, stud,
or similar fixed structural unit with the included mounting screws.
For remodeling applications, junction box may rest on top of ceiling material. This
fixture and junction box are Type IC rated and suitable for use in direct contact with
insulation.
8) Reconnect fixture cable connector to junction box cable connector, lining up arrows
on the connectors while pressing them together. Secure connection by screwing on
quick screw lock connector.
9)
Carefully push spring clips
[I]
upward while raising fixture to the installation hole.
10) Slowly release spring clips as fixture enters installation hole so that spring clips begin
to make contact with top edge of ceiling material. Be careful not to pinch fingers
between spring clips and fixture, or fixture and ceiling while installing. Spring clips
will pull fixture up the rest of the way to ceiling, mounting the fixture in place.
NOTE:
Ensure that spring clips have pulled the fixture flush to the ceiling.