D

4)  Remove spring clip

[A]

 from assembly

[B]

 by loosening 

hexnut

[C]

. Discard clip and retighten nut.

5)  Strip the two lead wires

[D]

 from luminaire wire. Using 

the provided wire connectors, connect the leads from the 

luminaires to the main supply cable leads. 

6)  Install luminaire in hole and fill hole after installation with pea 

gravel or sand. Backfill and compact the soil around the fixture 

thus securing it in the ground.

7)  Power on luminaire and check for proper operation.

HARDSCAPE MOUNTING

1)  TURN OFF POWER

2)  Determine desired location. 

3)  Install provided plastic installation sleeve

[E]

 in hardscape by 

mortaring in.

4)  Remove spring clip from assembly by loosening hexnut. 

Discard clip and retighten nut.

5)  Strip the two leads from luminaire wire. Using the provided 

wire connectors, connect the leads from the luminaires to the 

main supply cable leads. 

6)  After mortar is cured, install luminaire into the sleeve until 

cover

[F]

 (flange) is flush with mounting surface.

7)  Power on luminaire and check for proper operation.

DECK OR PERGOLA MOUNTING

1)  TURN OFF POWER

2)  Determine desired location. Minimum ¼” [6mm] thick 

mounting surface recommended.

3)  Drill 1 3/4” [45mm] hole in mounting surface. 

4)  Compress spring clips and insert fixture into hole until it is 

flush with the mounting surface. 

5)  Strip the two leads from luminaire wire. Using the provided 

wire connectors, connect the leads from the luminaires to the 

main supply cable leads. 

6)  Power on luminaire and check for proper operation. 

ALTERNATE CONDUIT MOUNTING (Conduit not supplied) 

Fixture can also be installed in 1-1/2” Trade size Schedule 80 PVC 

conduit.  For Schedule 40 conduit, replace smaller o-rings with 

heavier o-rings supplied with fixture.

Assembly and Installation (Figure 1) (continued)

Beam Adjustment (Figure 2)

Assembly and Installation (Figure 1)

Cautions

SAFETY INSTRUCTIONS

READ THIS FIRST

KEEP THESE INSTRUCTIONS

This fixture is intended for installation in accordance with the 

Canadian Standards (CSA) and Local code specifications. Failure 

to adhere to these codes and instructions may result in serious 

injury and/or property damage and will void the warranty.

1)  This fixture is to be used only with a power unit (transformer) 

rated a maximum of 300 W (25 AMPS) 15 volts per circuit.

2)  According to the requirements of the National Electric Code 

(NEC), direct burial rated wire is to be buried a minimum of 6” 

[152mm] beneath the surface of the ground.

NOTE: If additional Direct Burial wire is needed, contact your 

local Kichler® landscape distributor.

•  8 GA wire can be purchased in length of 250’ (76 M), 

15503-BK.

•  10 GA wire can be purchased in length of 250’ (76 M), 

15504-BK.

•  12 GA wire can be purchased in lengths of 100’ (30 M), 

15501-BK; 250’ (76 M), 15502-BK; 500’ (152M), 15505-BK; 

and 1000’ (304 M), 15506-BK.

3)  Fixture shall not use a tungsten halogen lamp unless the 

fixture is marked for use with such lamps.

4)  Wiring connections must be made with approved/listed wire 

connection device(s) suitable for the application. Do not 

exceed manufacturers’ wiring combination specifications for 

size and quantity of conductors.

CAUTION

When installing Kichler Landscape Lighting (Line voltage or 

low voltage), care should be taken to keep clear of potentially 

combustible materials.

When maintaining the fixtures, be sure to remove leaves, 

pine needles, grass clippings, mulch, or any debris that has 

accumulated on the light bulb, lens, or body of the fixture.

Parts List

[A] 

Spring Clip

[B] 

Assembly

[C] 

Hexnut

[D] 

Lead Wires

[E] 

Plastic 

Installation 

Sleeve

[F] 

Cover

[G] 

Glass

[H] 

White Gasket

[I] 

Plastic Optic

[J] 

LED

GROUND MOUNTING

1)  TURN OFF POWER

2)  Determine desired location. Check area for obstructions such 

as sprinklers, plant material, etc. Assess soil conditions.

3)  Dig a hole sufficiently wider and deeper than the well light to 

allow approximately 3” of pea gravel or sand to surround the 

fixture.

a)  For concrete applications, use a 1 3/4 inch core drill at 

least 6 inches deep.

Fixture is provided with three beam angle choices. 20° narrow 

spot, 40° flood (Installed) and 60° wide flood. To adjust the beam:

1)  Remove the cover

[F]

 by unscrewing.

2)  Remove glass

[G]

, white gasket

[H]

 and plastic optic

[I]

. CARE 

MUST BE TAKEN TO NOT DAMAGE LED AND SILICONE LED DOME.

3)  Select desired beam – beam angles are embossed in the 

corner of the plastic optic.

4)  Place selected optic over LED

[J]

 by aligning two bosses on 

bottom of optic with the alignment holes in fixture. AGAIN, 

CARE MUST BE TAKEN TO NOT DAMAGE LED AND SILICONE 

LED DOME.

5)  Replace gasket.

6)  Reinstall glass and cover; glass must be oriented so that 

beveled edge faces out. Be sure gasket is properly seated 

and cover is tightened to prevent moisture from entering the 

fixture.

OUTDOOR USE ONLY

DOM ETRE INSTALLE A L’EXTERIEUR

INSTRUCTIONS

For Assembling and Installing Fixtures in Canada

Pour L’assemblage et L’installation Au Canada

Reviews: