Kichler Lighting 11304NILED Quick Start Manual Download Page 1

Date Issued: 09/26/17

IS-11304LED-CB

We’re here to help 

866-558-5706

Hrs: M-F 9am to 5pm EST

CAUTION – RISK OF SHOCK – 
Disconnect Power at the main circuit breaker panel or main
fusebox before starting and during the installation. 

  4)  Grounding instructions: (See Illus. A or B). 

 

A)    On fixtures where mounting strap is provided with a hole 

and two raised dimples. Wrap ground wire from outlet box 

around green ground screw, and thread into hole. 

 

B)   On fixtures where a cupped washer is provided. Attach  

 

ground wire from outlet box under cupped washer and  

 

green ground screw, and thread into mounting strap. 

 

If fixture is provided with ground wire. Connect fixture ground 

wire to outlet box ground wire with wire connector. (Not pro

-

vided.) After following the above steps. Never connect ground 

wire to black or white power supply wires.

5)   Make wire connections. Reference chart below for correct con

-

nections and wire accordingly. 

6)  Carefully push wire connections 

[4]

 back into outlet box making 

sure all connections remain secure.

7)  Secure the backpan to the outlet box with the supplied mount

-

ing screws

[3]

8)  Anchor the backpan to the wall using the set of holes at each 

end of fixture using the provided wood screws

[5]

 and plastic 

anchors

[6]

9)  Slide end caps

[7]

 over glass

[8]

 and secure in place to backpan 

using lock-up knobs

[9].

AVERTISSEMENT :

This fixture is intended for installation in accordance with the

National Electrical Code (NEC) and all local code specifications.

If you are not familiar with code requirements, installation by a

certified electrician is recommended.

DIMMING :

This LED fixture is compatible with electronic low voltage dimmers 

only.

FCC INFORMATION :

This device complies with part 15 of the FCC Rules. Operation is

subject to the following two conditions:

(1)  This device may not cause harmful interference, and

(2)  this device must accept any interference received, including 

interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the 

limits for a Class B digital device, pursuant to part 15 of the FCC 

Rules. These limits are designed to provide

reasonable protection against harmful interference in a residential 

installation. This equipment generates, uses and can

radiate radio frequency energy and, if not installed and used

in accordance with the instructions, may cause harmful

interference to radio communications. However, there is no

guarantee that interference will not occur in a particular installation. 

If this equipment does cause harmful interference

to radio or television reception, which can be determined by

turning the equipment off and on, the user is encouraged to

try to correct the interference by one or more of the following mea

-

sures:

•  Reorient or relocate the receiving antenna.

•  Increase the separation between the equipment and receiver.

•  Connect the equipment into an outlet on a circuit different from 

that to which the receiver is connected.

•  Consult the dealer or an experienced radio/TV technician for help.

Instructions

1)  At the center of the backpan

[1]

 are knockout slots. Remove 

the set that matches your outlet box

[2].

2)  Position the backpan over the outlet box. Secure the backpan 

to the outlet box using mounting strap screws

[3]

 provided 

(these are the shorter of the two screws). 

3)  Mark the location of the outer keyhole slots of the backpan to 

the wall. Be sure to mark only the narrow part of the keyhole 

slot. Remove the backpan from the wall. Drill the holes using 

an appropriately sized drill bit. Insert the provided anchors

[6] 

into the holes.

GREEN GROUND

SCREW

CUPPED 

WASHER

OUTLET BOX

GROUND

FIXTURE

GROUND

DIMPLES

WIRE CONNECTOR

OUTLET BOX

GROUND

GREEN GROUND

SCREW

FIXTURE

GROUND

A

B

Connect Black or 

Red Supply Wire to:

Connect 

White Supply Wire to:

Black

White

*Parallel cord (round & smooth)

*Parallel cord (square & ridged)

Clear, Brown, Gold or Black 

without tracer

Clear, Brown, Gold or Black 

with tracer

Insulated wire (other than green) 

with copper conductor

Insulated wire (other than green) 

with silver conductor

*Note: When parallel wires (SPT I & SPT II) 
are used. The neutral wire is square shaped 
or ridged and the other wire will be round in
shape or smooth (see illus.)

Neutral Wire

2

3

4

5

6

1

7

8