Assembly Instructions
WireWorks
®
Tech Panel
KI
1330 Bellevue Street
P.O. Box 8100
Green Bay, Wisconsin 54308-8100
TEL (800) 424-2432
FAX (920) 468-0280
July, 2004
Tools Required:
3
⁄
16
” Allen Wrench
Definition
A WireWorks Tech Panel differs from a
standard WireWorks panel as follows:
1. Tech Panels do not utilize base
raceways on one or both sides
of panel.
2. Tech Panel bottom tiles extend down
an additional 6" in lieu of
the base raceway.
3. Tech Panels utilize plastic
horizontal light blocks instead of
steel horizontal rails wherever
possible.
Figure 1.
Installing Tech Panels
1. Panel frame of tech panel assembles
in the same manner as standard
WireWorks panel.
Note:
Every Tech Panel has steel
horizontals at top and bottom. Refer
to installation drawing to locate
middle rails.
2. Install plastic light blocks where
specified on installation drawing.
Figure 2
.
Push tab on light block with finger,
no tools required, in towards pocket
of vertical post and seat both tabs
into the pockets (in which the top
rivet of the steel horizontal would
normally be located).
Note:
Light blocks 42” and greater
require the installation of clips.
Figure 1
Figure 2
tile hook
plastic light blocks
clip
(to be installed on light
blocks 42" and greater)
plastic light block for
on-module overhead
storage, or
steel horizontal rail for
off-module.
plastic light block where
there isn’t power at belt
height, or
steel horizontal rail for
power at belt height.