„Installation and operation manual for fireplace insert”
KFDECOENG1.1562012
28
Table 6.
Parameters of KFD ECO
ECO i70
ECO 70
ECO 70
L/R
energy efficiency class
A
A
A
direct heat output (nominal power)
[kW]
13
13
13
heating power range
[kW]
7 - 16
7 - 16
7 - 16
energy efficiency index
[EEI]
106
106
106
energy efficiency at nominal heat output
[%]
79,6
79,6
79,6
seasonal space heating energy efficiency
[%]
70,6
70,6
70,6
CO emission at 13% O2
[%]
0,06
0,06
0,06
[mg/Nm3]
778
778
778
dust emission at 13% O2
[mg/Nm3]
<40
<40
<40
OGC at 13% O2
[mg/Nm3]
36
36
36
NOX emission at 13% O2
[mg/Nm3]
131
131
131
flue gas mass flow
[g/s]
13,03
13,03
13,03
verage smoke temperature at smoke outlet
[°C]
243
243
243
minimum chimney draft
[Pa]
12
12
12
weight
[kg]
135
120
125
6 Troubleshooting
PROBLEM
REASON
SOLUTION
I. Poor control of fire in
the furnace.
1. Excessive quantity of combustion
air.
1. Reduce the quantity of
combustion air using the adjustment
lever in the fireplace insert.
2. Open chimney damper.
2. Close the chimney damper.
3. Excessive quantity of inserted
fuel.
3. Do not put more fuel and reduce
the quantity of combustion air, close
the chimney damper.
4. Worn gaskets.
4. Fit new gaskets.
5. Excessive negative pressure in
the chimney.
5. Install a cap type chimney
attachment and/or install a draught
moderator.
II. Fire cannot be lit up
in the furnace
1. Closed levers of combustion air
inlet.
1. Increase the quantity of
combustion air.