13   

 14 

mode, LED only displays the set level, which doesn’t change with the wind speed, same as 
natural wind. 

High speed: 30 minutes at high speed, 30 minutes at medium speed, 30 minutes at 
low speed 
Medium speed: 30 minutes at medium speed, 30 minutes at low speed 
Low speed: running at low speed natural wind 

-

 

Smart: Integrates NTC (

thermal resistance

)

 

detecting ambient temperature

 

The specific functions of smart mode are as follows: When the ambient temperature is

 

below

 

77°F, it runs at low speed wind; when the ambient temperature is

 

77-84.2°F, it runs

 

at medium speed wind; when the ambient temperature is above

 

84.2°F, it runs at high 

speed wind. Meanwhile, when the smart mode is turned on, the ambient temperature 
digital tube + smart mode ind wind speed indicator flash three times 
simultaneously at one second interval to prompt that smart mode is enabled, and the 
corresponding wind speed indicator turns on; you can press the Speed button to cancel

 

the smart mode and return to normal wind.

7. Swing button

a. In power state, press this button to switch on/off the rotary blades; the corresponding

indicator displays its function; the blades rotate 360° clockwise.

b. Press and hold the “Swing” button and “Timer” button simultaneously for 3 seconds to

cancel the sound; press and hold the two buttons again to turn on the sound.

Protection function 

1. Tank water shortage protection:

a. If the software detects a tank water shortage, the protection will switch off for 5

seconds continuously. When the water pump has been running for 45 seconds, the 
pump stops working. The buzzer will send a Beep Beep alarm sounds for 10 seconds.

b. Press the Cooling/Humidify button for three times within three seconds after power on,

and the device sends Beep Beep sound (same as the sound of 5-50°C forced heating of
the heater) and enters the quick water shortage detection status.

c. In quick water shortage detection status, press the power button and then press the 

Cooling/Humidify button, and the device will detect water shortage in 3 seconds

(originally 50 seconds), and sends water shortage alarm. 

d. The quick water shortage detection is canceled after pressing the Power off button.

2. Tank extraction protection:

When the water tank is extracted, the machine power is cut off and the buzzer sends Beep 
Beep sound; when the water tank is put back, the buzzer sends Beep Beep sound, and the 
power enters standby mode.

3. Power failure memory function

In power on state, when power is restored after power failure, it sends "bi" sound 10 times 
(once per second), no display or action; after 30 seconds, it resumes the previous state (all
functions are restored).
a. If you press the Power on/off button within 30 seconds, it resumes the previous state

immediately.

b. If the power is cut off in power off state, it is still off when the power is restored.

4. Auto power-off function

If the device has been running for 15 hours continuously in default state after power on and 
there is no operation, it automatically turns off; if you want to cancel this function, press 
and hold the "C Mode" button for 3 seconds, the buzzer sends Beep sound, and 
cancels auto power-off function; press and hold the two buttons again, the buzzer sends Bi
sound and resumes auto power-off function

Filling water:

Before turning on the cooling and humidification function, please add water to the tank.
Before adding water, first open the knob of water tank lock, tank out the water tank and fill
water into the tank slowly (Fig. 1, 2, 3 & 4): after adding water, put the water tank into the 
original position, and then re-lock the knob of the water tank lock.

Summary of Contents for 972-1001-W

Page 1: ...perly please read this manual before using the product We hope that our product will being comfort and pleasure to you in your daily life Contents I Safety warnings and precautions 3 II Functions and...

Page 2: ...nce from the power supply before user servicing or cleaning operation 6 This appliance has a polarized plug one blade is wider than the other To reduce the risk of electric shock this plug is intended...

Page 3: ...e power plug and insert the plug completely It may cause current leakage If there is any peculiar smell or abnormal sound when using the product stop it immediately and disconnect the power Do not use...

Page 4: ...handle or else the water in the tank will overflow Please push the handle If there is no water or little water in the tank you can hold the handle to lift the device During humidification do not remo...

Page 5: ...ow 7 Universal casters 8 Handle 9 Remote repository 10 Back Shell 11 Air filter 12 Power cord holder 13 Power cord 14 Water tank 15 Casters 16 Tank lock Remote control Below is the operation panel of...

Page 6: ...re off Start at medium level turn to level low after three seconds Timer function is off indicator turns off 3 Speed button In power on state press the Speed button to switch among low medium and high...

Page 7: ...after power on and the device sends Beep Beep sound same as the sound of 5 50 C forced heating of the heater and enters the quick water shortage detection status c In quick water shortage detection s...

Page 8: ...e aim at the receiver 4 When the battery is exhausted pull out the battery cover in the direction shown in the figure and replace the battery CR2032 3V Please note the battery polarity and put back th...

Page 9: ...not rinse with water directly 2 Do not use corrosive detergent or solvent for cleaning 3 Turn off the power and unplug the power cord before cleaning or else it may cause electric shock Install and u...

Page 10: ...e misuse or inadequate power supply 3 If the unit is put to commercial business rental or other use other than for consumer use 4 Products without original serial numbers or products that have serial...

Reviews: