6 List Sequence Measurements
Source
FM Rate
Allows you to set the internal frequency modulation rate.
Key Path
Source, Modulation Setup, FM
Remote Command
:SOURce:FM:INTernal:FREQuency
:SOURce:FM:INTernal:FREQuency?
Example
:SOUR:FM:INT:FREQ 40.0 Hz
Preset
400.0 Hz
Min
10 Hz
Max
40 kHz
Initial S/W Revision
A.05.00
PM
Allows access to the menu for configuring the phase modulation.
Key Path
Source, Modulation Setup
Initial S/W Revision
A.05.00
PM
Enables or disables the phase modulation.
Turning PM on when another modulation format is already on results in the previous modulation format
being turned off and the generation of an error.
Key Path
Source, Modulation Setup, PM
Remote Command
:SOURce:PM:STATe
:SOURce:PM:STATe?
Example
:SOUR:PM:STAT OFF
Preset
Off
Range
On | Off
Initial S/W Revision
A.05.00
PM Deviation
Allows you to set the phase modulation deviation.
Key Path
Source, Modulation Setup, PM
Remote Command
:SOURce:PM[:DEViation]
:SOURce:PM[:DEViation]?