![Keysight E6640A Measurement Applications User & Programmer Reference Download Page 2704](http://html1.mh-extra.com/html/keysight/e6640a/e6640a_measurement-applications-user-and-programmer-reference_19616452704.webp)
15 Power Control Measurement
Save
Two forms of parameters are allowed. The first form has two parameters. In this form, the first
parameter specifies the source, and the second parameter specifies the destination.
The second form has four parameters. In this form, the first and third parameters specify the source.
The second and fourth parameters specify the directories. The first pair of parameters specifies the
source. The second pair specifies the destination. An error is generated if the source doesn’t exist or
the destination file already exists.
This command will generate an “access denied” error if the destination is a restricted folder (e.g.,
C:\Windows) and the current user does not have Power User or Administrator privileges.
Initial S/W Revision
Prior to A.02.00
Mass Storage Remove Directory (Remote Command Only)
Key path
SCPI Only
Remote Command
:MMEMory:RDIRectory <directory_name>
Notes
The string must be a valid logical path.
Removes a directory. The <directory_name> parameter specifies the directory name to be removed.
All files and directories under the specified directory shall also be removed.
This command will generate an “access denied” error if the folder is a restricted folder (e.g.,
C:\Windows) or is in a restricted folder and the current user does not have Power User or
Administrator privileges.
Initial S/W Revision
Prior to A.02.00
Sequences
These keys allow you to save a Tab separated or CSV file of the setup parameters required to build a
Sequence.
In order to save you must select the Save As button and choose a destination folder.
Key Path
Save, Sequences
Mode
All
Remote Command
:MMEM:STOR:SEQuences: | SLISt | ALISt | SAAList | SSTep
"MySequence.txt"
Example
:MMEM:STOR:SEQ:SLISt "MySequence.txt"
Notes
Available file types are:
−
CSV (Comma delimited) (*.csv)
−
Text (Tab delimited) (*.txt)
Initial S/W Revision
A.05.00
2704
W-CDMA & HSPA Measurement Applications Reference
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...