![Keysight E6640A Measurement Applications User & Programmer Reference Download Page 2114](http://html1.mh-extra.com/html/keysight/e6640a/e6640a_measurement-applications-user-and-programmer-reference_19616452114.webp)
13 Modulation Accuracy (Composite EVM) Measurement
Meas Setup
Example
RHO:MCES ON
RHO:MCES?
Preset
OFF
State Saved
Saved in instrument state.
Range
On|Off
Initial S/W Revision
Prior to A.02.00
Timing Estimation
Selects between channel-by-channel and global timing estimation functions for MMSE.
•
CHANnel-by-Channel: The code channels are estimated using individual timing. This requires longer
time.
•
GLOBal: The individual code channels are estimated using global timing. This requires less time.
Key Path
Meas Setup, Advanced
Mode
WCDMA
Remote Command
[:SENSe]:RHO:MCEStimator:TIMing CHANnel|GLOBal
[:SENSe]:RHO:MCEStimator:TIMing?
Example
RHO:MCES:TIM CHAN
RHO:MCES:TIM?
Preset
GLOBal
State Saved
Saved in instrument state.
Range
Ch-by-Ch|Global
Initial S/W Revision
Prior to A.02.00
Frequency Error Tolerance Range
Selects the frequency error tolerance range from either Normal or Wide.
•
NORMal– provides a more stringent range of frequency tolerance, which is useful when you want to
accurately demodulate signals of higher complexity. For example, when composite channels are
modulated on the same signal, the modulation is complex, and frequency error is critical to correct
demodulate. In the case of demodulating complex signals, set to ‘Normal’.
•
WIDE– provides a wider, and less stringent range of frequency error tolerance.
This parameter is valid only when the device type is MS (Uplink). When BTS (Downlink), the menu softkey is
disabled (grayed out).
Key Path
Meas Setup, Advanced
Mode
WCDMA
2114
W-CDMA & HSPA Measurement Applications Reference
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...