4 Input/Output Functions
Input/Output
[:SENSe]:FEED QONLy aliases to [:SENSe]:FEED:IQ:TYPE QONLy
The query [:SENSe]:FEED? will always returns AIQ whatever the type of legacy parameters IQ | IONLy
| QONLy has been used.
Backwards Compatibility
Notes
Most of the settings in the X-Series Input/Output system, including External Gain, Amplitude
Corrections settings and data, etc., are shared by all modes and are not changed by a mode switch.
Furthermore, most variables in the Input/Output system key are not affected by Mode Preset. Both of
these behaviors represent a departure from legacy behavior.
In the X-Series. Input/Output settings are reset by using the "Restore Input/Output Defaults"
function. They can also be reset to their default values through the System->Restore System
Defaults-> In/Out Config key or through the System ->Restore System Defaults -> All key (and
corresponding SCPI).
While this matches most use cases better, it does create some code compatibility issues. For
example, Amplitude Corrections are no longer turned off by a Mode Preset, but instead by using the
"Restore Input/Output Defaults" key/SCPI.
Although Input/Output settings are not part of each Mode’s State, they are saved in the Save State
files, so that all of the instrument settings can be recalled with Recall State, as in legacy
instruments.
Initial S/W Revision
Prior to A.02.00
Remote Command
:INPut:MIXer EXTernal|INTernal
:INPut:MIXer?
Example
INP:MIX INT
INP:MIX?
Notes
In legacy analyzers you choose between the Internal mixer or an External Mixer. In the X-Series, the
External Mixer is one of the choices for the Input and is selected using the FEED command
(:SENSe:FEED EXTMixer).
For compatibility, the INPut:MIXer EXTernal|INTernal legacy command is mapped as follows:
1. When INPut:MIXer EXTernal is received, SENSe:FEED EMIXer is executed.
2. When INPut:MIXer INTernal is received, SENSe:FEED RF is executed.
3. When INPut:MIXer? is received, the response will be INT if any input other than the external mixer
is selected and EXT if the external mixer is selected
Preset
INT
Backwards Compatibility
Notes
PSA supports the following SCPI Command :
:INPut:MIXer:TYPE PRESelected|UNPReselect
:INPut:MIXer:TYPE?
PXA does not support the :INPut:MIXer:TYPE command.
Initial S/W Revision
A.08.01
Input/Output variables - Preset behavior
Virtually all the input/output settings are NOT a part of mode preset. They can be set to their default value
W-CDMA & HSPA Measurement Applications Reference
191
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...