3 Programming the Test Set
Common Commands
Notes
Registers 0 through 6 are accessible from the front panel in menu keys for Recall Registers.
Min
0
Max
127
Status Bits/OPC
dependencies
The command is sequential.
Initial S/W Revision
Prior to A.02.00
*RST (Remote Command Only)
*RST is equivalent to :SYST:PRES;:INIT:CONT OFF, which is a Mode Preset in the Single measurement
state. This remote command is preferred over Mode Preset remote command - :SYST:PRES, as optimal
remote programming occurs with the instrument in the single measurement state.
Remote Command
*RST
Example
*RST
Notes
Sequential
Clears all pending OPC bits and the Status Byte is set to 0.
Couplings
A *RST will cause the currently running measurement to be aborted and cause the default
measurement to be active. *RST gets the mode to a consistent state with all of the default couplings
set.
Backwards Compatibility
Notes
In legacy analyzers *RST did not set the analyzer to Single, but in the X-Series it does, for compliance
with the IEEE 488.2 specification.
In the X-Series, *RST does not do a *CLS (clear the status bits and the error queue). In legacy
analyzers, *RST used to do the equivalent of SYSTem:PRESet, *CLS and INITiate:CONTinuous OFF.
But to be 488.2 compliant, *RST in the X-Series does not do a *CLS.
Initial S/W Revision
Prior to A.02.00
Save Instrument State
This command saves the current instrument state and mode to the specified instrument memory register.
Remote Command
*SAV <register #>
Example
*SAV 9 Saves the instrument state in register 9.
Notes
Registers 0 through 6 are accessible from the front panel in menu keys for Save Registers.
Min
0
Max
127
Status Bits/OPC
dependencies
The command is sequential.
Initial S/W Revision
Prior to A.02.00
W-CDMA & HSPA Measurement Applications Reference
185
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...