![Keysight E6640A Measurement Applications User & Programmer Reference Download Page 1685](http://html1.mh-extra.com/html/keysight/e6640a/e6640a_measurement-applications-user-and-programmer-reference_19616451685.webp)
12 Code Domain Measurement
Marker
Mode
WCDMA
Remote Command
:CALCulate:CDPower:MARKer[1]|2|...|12:X <real>
:CALCulate:CDPower:MARKer[1]|2|...|12:X?
Example
CALC:CDP:MARK3:X 0.0
CALC:CDP:MARK3:X?
Notes
If no suffix is sent, uses the fundamental units for the current marker X Axis Scale. If a suffix is sent
that does not match the current marker X Axis Scale unit, an error “Invalid suffix” is generated.
The query returns the marker’s absolute X Axis value if the control mode is Normal, or the offset from
the marker’s reference marker if the control mode is Delta. The query is returned in the fundamental
units for the current marker X Axis scale: Hz for Frequency and Inverse Time, seconds for Period and
Time. If the marker is Off the response is not a number.
Preset
After a preset, all Markers are turned OFF, so Marker X Axis Value query returns a Not A Number
(NAN).
State Saved
No
Min
–9.9E+37
Max
9.9E+37
Initial S/W Revision
Prior to A.02.00
Marker X Axis Position (Remote Command only)
Sets the marker X position in trace points. It has no effect if the control mode is Off, but is the SCPI
equivalent of entering a value if the control mode is Normal or Delta - except in trace points rather than X
Axis Scale units. The entered value is immediately translated into the current X Axis Scale units for setting
the value of the marker.
Mode
WCDMA
Remote Command
:CALCulate:CDPower:MARKer[1]|2|...|12:X:POSition <real>
:CALCulate:CDPower:MARKer[1]|2|...|12:X:POSition?
Example
CALC:CDP:MARK10:X:POS 0.0
CALC:CDP:MARK10:X:POS?
Notes
The query returns the marker’s absolute X Axis value in trace points if the control mode is Normal, or
the offset from the marker’s reference marker in trace points if the control mode is Delta. The value
is returned as a real number, not an integer, corresponding to the translation from X Axis Scale units
to trace points. If the marker is Off the response is
Not A Number (NAN)
.
Preset
After a preset, all Markers are turned OFF, so Marker X Axis Value query returns a Not A Number
(NAN).
State Saved
No
Min
(9.9E+37
Max
9.9E+37
Initial S/W Revision
Prior to A.02.00
W-CDMA & HSPA Measurement Applications Reference
1685
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...