12 Code Domain Measurement
Marker
Max
12
Initial S/W Revision
Prior to A.02.00
Marker Trace
Assigns the specified marker to the designated trace.
Key Path
Marker, Properties
Mode
WCDMA
Remote Command
:CALCulate:CDPower:MARKer[1]|2|...|12:TRACe CDPower | EVM | MERRor |
PERRor | SPOWer | CPOWer | CDError | POLar
:CALCulate:CDPower:MARKer[1]|2|...|12:TRACe?
Example
CALC:CDP:MARK:TRACE POL
CALC:CDP:MARK:TRACE?
Preset
CDPower
State Saved
Saved in instrument state.
Range
Code Domain Power|Code Domain Error|Symbol Power|Chip Power|EVM|Phase Error|Mag Error|Polar
Initial S/W Revision
Prior to A.02.00
Couple Markers
Toggles the state of the markers to be coupled On or Off. When this function is true (On), moving any
marker causes an equal X-axis movement of every other marker except those located to the polar trace,
and Chip value of the marker located to the polar trace, which is not Off, including Fixed markers. “Equal X
Axis movement” refers to the difference between each marker’s X Axis value (in the fundamental x-axis
units of the trace that marker is on) and the X Axis value of the marker being moved (in the same
fundamental x-axis units). This may result in markers going offscreen.
Key Path
Marker
Mode
WCDMA
Remote Command
:CALCulate:CDPower:MARKer:COUPle[:STATe] ON|OFF|1|0
:CALCulate:CDPower:MARKer:COUPle[:STATe]?
Example
CALC:CDP:MARK:COUP ON
CALC:CDP:MARK:COUP?
Preset
OFF
State Saved
Saved in instrument state.
Range
On|Off
Initial S/W Revision
Prior to A.02.00
W-CDMA & HSPA Measurement Applications Reference
1683
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...