11 Occupied Bandwidth Measurement
Sweep/Control
Period
Sets the period of the internal periodic timer clock. For digital communications signals, this is usually set to
the frame period of your current input signal. In the case that sync source is not set to OFF, and the
external sync source rate is changed for some reason, the periodic timer is synchronized at the every
external synchronization pulse by resetting the internal state of the timer circuit.
Key Path
Trigger, Periodic Timer
Remote Command
:TRIGger[:SEQuence]:FRAMe:PERiod <time>
:TRIGger[:SEQuence]:FRAMe:PERiod?
Example
TRIG:FRAM:PER 100 ms
Dependencies
The invalid data indicator turns on when the period is changed, until the next sweep/measurement
completes.
Couplings
The same period is used in the Gate Source selection of the period timer.
Preset
20 ms
GSM: 4.615383
State Saved
Saved in instrument state
Min
100.000 ns
Max
559.0000 ms
Default Unit
S
Initial S/W Revision
Prior to A.02.00
Offset
Adjusts the accumulated offset between the periodic timer events and the trigger event. Adjusting the
accumulated offset is different than setting an offset, and requires explanation.
The periodic timer is usually not synchronized with any external events, so the timing of its output events
has no absolute meaning. Since the timing relative to external events (RF signals) is important, you need to
be able to adjust (offset) it. However, you have no direct way to see when the periodic timer events occur.
All that you can see is the trigger timing. When you want to adjust the trigger timing, you will be changing
the internal offset between the periodic timer events and the trigger event. Because the absolute value of
W-CDMA & HSPA Measurement Applications Reference
1585
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...