![Keysight E6640A Measurement Applications User & Programmer Reference Download Page 1273](http://html1.mh-extra.com/html/keysight/e6640a/e6640a_measurement-applications-user-and-programmer-reference_19616451273.webp)
10 Spectrum Emission Mask Measurement
Sweep/Control
Trig Slope
Controls the trigger polarity. It is set positive to trigger on a rising edge and negative to trigger on a falling
edge.
Key Path
Trigger, Video
Remote Command
:TRIGger[:SEQuence]:VIDeo:SLOPe POSitive|NEGative
:TRIGger[:SEQuence]:VIDeo:SLOPe?
Example
TRIG:VID:SLOP NEG
Preset
POSitive
State Saved
Saved in instrument state
Backwards
Compatibility SCPI
:TRIGger[:SEQuence]:IF:SLOPe NEGative|POSitive
:TRIGger[:SEQuence]:IF:SLOPe?
For backward compatibility with VSA/PSA comms apps
Backwards Compatibility
Notes
The legacy :TRIGger[:SEQuence]:SLOPe command affects the slopes for the VID, LINE, EXT1, EXT2,
and RFB triggers.
Initial S/W Revision
Prior to A.02.00
Remote Command
:TRIGger[:SEQuence]:SLOPe POSitive|NEGative
:TRIGger[:SEQuence]:SLOPe?
Example
TRIG:SLOP NEG
Preset
POSitive
State Saved
Saved in instrument state
Backwards Compatibility
Notes
In ESA/PSA, the Trigger Slope was global to all triggers. In the X-Series, the slope can be set
individually for each Trigger Source. For backward compatibility, the global SLOPe command
updates all instances of trigger slope (VID, LINE, EXT1, EXT2, TV, RFB). The query returns the trigger
slope setting of the currently selected trigger source.
Initial S/W Revision
Prior to A.02.00
External 1
Pressing this key, when it is not selected, selects an external input signal as the trigger. A new
sweep/measurement will start when the external trigger condition is met using the external 1 input
connector on the rear panel.
Pressing this key, when it is already selected, accesses the external 1 trigger setup menu.
Key Path
Trigger
Example
TRIG:SOUR EXT1 Swept SA measurement
TRIG:<meas>:SOUR EXT1 Measurements other than Swept SA
Dependencies
Grayed out if in use by Point Trigger in the Source Setup menu.
Forced to Free Run if already selected and Point Trigger is set to External 1.
W-CDMA & HSPA Measurement Applications Reference
1273
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...