![Keysight E6640A Measurement Applications User & Programmer Reference Download Page 1022](http://html1.mh-extra.com/html/keysight/e6640a/e6640a_measurement-applications-user-and-programmer-reference_19616451022.webp)
10 Spectrum Emission Mask Measurement
Marker
Marker
Accesses a menu that enables you to select, set up and control the markers for the current measurement.
If there are no active markers, Marker selects marker 1, sets it to Normal and places it at the center of the
display. You can turn on and control up to 12 markers.
Key Path
Front-panel key
Initial S/W Revision
Prior to A.02.00
Select Marker
Displays 12 markers available for selection.
Key Path
Marker
Initial S/W Revision
Prior to A.02.00
Marker Type
Sets the marker control mode to Normal and Off. If the selected marker is Off, pressing Marker sets it to
Normal and places it at the center of the screen on the trace determined by the Marker Trace rules. At the
same time, Marker X Axis Value appears on the Active Function area. The marker X axis value entered in
the active function area will display the marker value to its full entered precision. If the current control
mode for the measurement is Off, there is no active function and the active function is turned off.
Key Path
Marker
Mode
SA, WCDMA, C2K, WIMAX OFDMA, TD-SCDMA, 1xEVDO, DTMB (CTTB), DVB-T/H, ISDB-T, CMMB,
LTE, LTETDD, Digital Cable TV, WLAN, MSR, LTEAFDD, LTEATDD
Remote Command
:CALCulate:SEMask:MARKer[1]|2|...|12:MODE POSition|OFF
:CALCulate:SEMask:MARKer[1]|2|...|12:MODE?
Example
CALC:SEM:MARK:MODE POS
CALC:SEM:MARK:MODE?
Notes
If the selected marker is Off, pressing Marker sets it to Normal and places it at the center of the
screen on the trace determined by the Marker Trace rules. At the same time, Marker X Axis Value
appears on the Active Function area.
Default Active Function: the active function for the selected marker’s current control mode. Note that
if the current control mode is Off, there is no active function and the active function is turned off.
Active Function Display: the marker X axis value entered in the active function area will display the
marker value to its full entered precision.
Preset
OFF|OFF|OFF|OFF|OFF|OFF|OFF|OFF|OFF|OFF|OFF|OFF
State Saved
Saved in instrument state
Range
Normal|Off
Initial S/W Revision
Prior to A.02.00
Modified at S/W Revision
A.02.00, A.03.00
1022
W-CDMA & HSPA Measurement Applications Reference
Summary of Contents for E6640A
Page 80: ...Table of Contents lxxx W CDMA HSPA Measurement Applications Reference ...
Page 188: ...3 Programming the Test Set Common Commands 188 W CDMA HSPA Measurement Applications Reference ...
Page 256: ...5 Mode Functions Mode Setup 256 W CDMA HSPA Measurement Applications Reference ...
Page 324: ...6 System Functions System 324 W CDMA HSPA Measurement Applications Reference ...
Page 369: ...8 Channel Power Measurement Auto Couple W CDMA HSPA Measurement Applications Reference 369 ...
Page 389: ...8 Channel Power Measurement Marker W CDMA HSPA Measurement Applications Reference 389 ...
Page 664: ...9 ACP Measurement Auto Couple 664 W CDMA HSPA Measurement Applications Reference ...
Page 669: ...9 ACP Measurement BW W CDMA HSPA Measurement Applications Reference 669 ...
Page 984: ...9 ACP Measurement View Display 984 W CDMA HSPA Measurement Applications Reference ...
Page 1001: ...10 Spectrum Emission Mask Measurement W CDMA HSPA Measurement Applications Reference 1001 ...
Page 1668: ...12 Code Domain Measurement Auto Couple 1668 W CDMA HSPA Measurement Applications Reference ...
Page 2354: ...14 QPSK EVM Measurement 2354 W CDMA HSPA Measurement Applications Reference ...
Page 2364: ...14 QPSK EVM Measurement Auto Couple 2364 W CDMA HSPA Measurement Applications Reference ...