Keysight E1412A Digital Multimeter User Guide
cxcv
TRIGger
Multimeter Command Reference
Comments
–
The
TRIGger:SOURce
command only selects the trigger source. You must
use the
INITiate
command to place the multimeter in the wait-for-trigger
state. (The
MEASure
command automatically executes an
INITiate
command.)
–
TRIGger:SOURce EXT
uses the multimeter's front panel “Trig” BNC
connector as the trigger source. The multimeter triggers on the falling
(negative-going) edge of a ±5V TTL input signal; (maximum input is +5V to
the front panel BNC connector).
–
TRIGger:IMMediate
causes a trigger to occur immediately provided the
multimeter is placed in the wait-for-trigger state using
INITiate
,
READ?
or
MEAS?
.
–
When a Group Execute Trigger (GET) bus command or
*TRG
common
command is executed and the multimeter is not in the wait-for-trigger
state, the “Trigger ignored” error is generated.
–
The
CONFigure
and
MEASure
command subsystems automatically set the
trigger source to
TRIG:SOUR IMM
.
–
The
READ?
command cannot be used if the trigger source is
TRIG:SOUR BUS
.
–
Related Commands:
INITiate
,
READ?
,
MEAS?
–
*RST
Condition:
TRIG:SOUR IMM
Example
Set the Sample Source
CONF:VOLT:DC
Function: DC voltage.
TRIG:SOUR EXT
Trigger source is external BNC on
multimeter front panel.
TRIG:COUN 10
Multimeter will accept 10 external triggers.
READ?
Place multimeter in wait-for-trigger state; make
measurements when external trigger is received;
send readings to output buffer.
enter statement
Enter readings into computer.
:SOURce?
TRIGger:SOURce?
returns “
BUS
”, “
EXT
”, “
IMM
” or “
TTLTrg0
-
7
” to show the
present trigger source. The quoted string is sent to the output buffer.
Example
Query the Trigger Source