MIL-STD-1553/ARINC 429 Triggering and Serial Decode
31
Keysight InfiniiVision 3000T X-Series Oscilloscopes User's Guide
489
•
Line B (inverted)
.
•
Differential (A-B)
.
10
Press the
Auto Setup
softkey to automatically set these options for decoding and
triggering on ARINC 429 signals:
•
High Trigger Threshold: 3.0 V.
•
Low Trigger Threshold: -3.0 V.
•
Noise Reject: Off.
•
Probe Attenuation: 10.0.
•
Vertical Scale: 4 V/div.
•
Serial Decode: On.
•
Base: Hex.
•
Word Format: Label/SDI/Data/SSM.
•
Trigger: currently active serial bus.
•
Trigger Mode: Word Start.
11
If the high and low thresholds are not set correctly by
Auto Setup
:
•
Press the
High Threshold
softkey; then, turn the Entry knob to set the high
trigger threshold voltage level.
•
Press the
Low Threshold
softkey; then, turn the Entry knob to set the low
trigger threshold voltage level.
The threshold voltage levels are used in decoding and will become the trigger
levels when the trigger type is set to the selected serial decode slot.
ARINC 429 Triggering
To set up the oscilloscope to capture a ARINC 429 signal, see
After setting up the oscilloscope to capture a ARINC 429 signal:
1
Press
[Trigger]
.
2
In the Trigger Menu, press the
Trigger
softkey; then, turn the Entry knob to
select the serial slot (Serial 1 or Serial 2) on which the ARINC 429 signal is
being decoded.
Summary of Contents for DSOX3012T
Page 78: ...78 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Page 88: ...88 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 3 Vertical Controls...
Page 98: ...98 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 4 FFT Spectral Analysis...
Page 148: ...148 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 7 Digital Channels...
Page 154: ...154 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 8 Serial Decode...
Page 160: ...160 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 9 Display Settings...
Page 232: ...232 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 13 Acquisition Control...
Page 242: ...242 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 14 Cursors...
Page 288: ...288 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 16 Mask Testing...
Page 320: ...320 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 19 Waveform Generator...
Page 340: ...340 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 21 Print Screens...
Page 374: ...374 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 23 Web Interface...
Page 394: ...394 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 24 Reference...