186
Keysight InfiniiVision 3000T X-Series Oscilloscopes User's Guide
11
Triggers
6
Press the
Trigger Event
softkey; then, turn the Entry knob to select the event to
trigger on. Some of the events you can select are defined in the standards;
other event options include:
•
Either
— With the NFC-A signaling technology, this option means either the
SENS_REQ or ALL_REQ events will cause a trigger. With the NFC-B
signaling technology, this option means either the SENSB_REQ or
ALLB_REQ events will cause a trigger.
•
Preamble
— With the NFC-F signaling technologies, this option specifies the
preamble sequence that begins a data frame.
•
Arm & Trigger
— This selection lets you arm the oscilloscope on one event and
then trigger on a second event or after a specified timeout period if the
second event does not occur.
7
With the NFC-F standards, there is a
Reverse Polarity
softkey that enables the
oscilloscope to trigger on "reverse" polarity signals. When disabled, the
oscilloscope triggers on "obverse" polarity signals.
8
When the
Arm & Trigger
event is selected:
a
Press the
Arm Event
softkey to select the event to arm on.
When the specified event arms, the
TRIG OUTBNC
goes high. The
oscilloscope waits until a second event is found or until the specified timeout
period expires and then triggers.
•
For NFC-A, the second event is SDD_REQ.
•
For NFC-B, the second event is ATTRIB.
•
For NFC-F, the second event is ATR_REQ.
When the oscilloscope triggers, the
TRIG OUTBNC
line goes low.
b
Press the
Timeout
softkey; then, turn the Entry knob (or press the softkey
again and use the keypad dialog) to enter the timeout period.
Nth Edge Burst Trigger
The Nth Edge Burst trigger lets you trigger on the Nth edge of a burst that occurs
after an idle time.
Summary of Contents for DSOX3012T
Page 78: ...78 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Page 88: ...88 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 3 Vertical Controls...
Page 98: ...98 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 4 FFT Spectral Analysis...
Page 148: ...148 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 7 Digital Channels...
Page 154: ...154 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 8 Serial Decode...
Page 160: ...160 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 9 Display Settings...
Page 232: ...232 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 13 Acquisition Control...
Page 242: ...242 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 14 Cursors...
Page 288: ...288 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 16 Mask Testing...
Page 320: ...320 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 19 Waveform Generator...
Page 340: ...340 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 21 Print Screens...
Page 374: ...374 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 23 Web Interface...
Page 394: ...394 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 24 Reference...