1
Keysight ZA0060A Quick Start Guide
48
Test Steps and Description
Initialize WLAN Signaling
This step must be a child step of
. This test step initializes WLAN profile for
Signaling PER test based on the following settings.
Basic and Advanced Settings:
– Channel: The number of channels available in the drop-down list is subject to the region selected.
– US: Channel 1 to 11
– Japan: Channel 1 to 14
– Europe: Channel 1 to 13
– WLAN role: Set the role of the 34999B as an Access Point or Station.
– Network SSID: Set the SSID for WLAN connection with a maximum length of 32 characters
– Security Type: Select Open, WEP, or WPA2 option. For the WEP and WPA2 option, you will need to
enter the security key. You can also choose to view the security key in readable form as shown below.
– Region: Select US, Japan or Europe.
– RF Path: Select one of the three options to set the RF path of the signaling operations.
– Dynamic: Set the signal path to enable the 34999B module to switch between uplink and downlink
dynamically based on the direction of the incoming or outgoing signal. For this option, you can set
the DUT Tx Power to track the incoming DUT transmission signal.
– Downlink: Set the signal path from the DUT to the 34999B module.
– Uplink: Set the signal path from the 34999B to the DUT.