U3042AM08
Option 129 External Source Path
Option 129 External Source Path
The U3042AM08 with Option 129 allows an external ECal module, or noise source to
be switched into the Source path of Ports 1, 5
,
or 9. Only one port can be the source
at a time.
System Configuration
The cable (U3042-20076) provided with Option 129 is intended to be used with the
N46xx series ECal modules. The ECal module with Option M0F is recommended.
1. Connect the ECal module to the NOISE SOURCE IN on the test set.
2. Connected the cable (U3042-20076) from the NOISE SOURCE OUT on the test set
to the ECal module.
3. Connect the ECal modules USB cable to one of the PNA-X USB ports.
Figure 4
5
N5242A System with ECal Module
USB Cable
N4691B
U3042-20076
54
Keysight U3042AM08 User's and Service Guide
Summary of Contents for U3042AM08
Page 7: ...U3042AM08...