U3022AE10
Network Analyzer Requirements
Network Analyzer Requirements
For multiport operation (N-port error correction and measurement capability) all "A" model network
analyzers require Option 551 and all "B" model analyzers require Software Application S93551B. For "B"
models in which the system is configured with more than eight test ports, it is recommended to use PLTS
Software N1930B to manage/control any advanced network analyzer measurement applications and their
large data files.
Table 2 provides a listing of other network analyzer option requirements. The analyzer's frequency range
must be equal to or exceed that of the test set so that
the measurement system covers the full frequency
range of the test set.
The test set files indicated in Table 2 must be installed into this network analyzer file
directory location: C:\Program Files (x86)\Agilent\Network Analyzer\TestSets.
For the "B" model PNA-X: C:\Program Files (x86)\Agilent\Keysight\Network Analyzer\Keysight\TestSets.
•Network Analyzer Firmware -
http://na.support.keysight.com/pna/firmware/firmware.html
•U3022AE10 Test Set Files -
http://na.support.keysight.com/multiport/testsetsupport.html
Table 2
Configuration Requirements
2-Port
Network Analyzer
Series
Options
Test Set File
N5222A/B
PNA
201, 217 or
219
U3022ae10_pnax_p2.tsx
Figure
2
on
page 9
N5232A/B
PNA-L
216
U3022ae10_p2.tsx
N5242A/B
PNA-X
200
U3022ae10_pnax_p2.tsx
4-Port
Network Analyzer
Series
Options
Test Set File
System Figures
N5222A/B
PNA
401, 417 or
419
U3022ae10_pnax_p4.tsx
N5232A/B
PNA-L
416
U3022ae10_p4.tsx
Figure
1
on
page 8
a
N5242A/B
PNA-X
Figure
3
on
a.
does not show the actual analyzer, but the port configuration is similar.
Ensure the network analyzer has the latest version of firmware installed. The following web site links will
provide necessary information needed:
Keysight U3022AE10 User's and Service Guide
11
PNA and PNA-X Receiver Compression Note
Systems configured with PNA or PNA-X series Network Analyzers will show compression at the beginning
of the frequency range when power level is increased. Typically, this will occur when power level is
increased above 5dBm. This occurs because the PNA and PNA-X analyzers use couplers at the test port
and the multiport extension test set has a directional bridge at the test port. The PNA and PNA-X receivers
are calibrated at the factory, and due to the higher coupling factor, the coupler at low frequency, the
receiver gain is set high to compensate. The multiport test set directional bridge has a lower coupling
factor at low frequencies, which results in compression when power level of the PNA/PNA-X is increased.
We recommend you increase the receiver attenuation in the PNA and PNAX to reduce this receiver
compression issue.