SCPI Command *RST Settings
SENSe:SWEep:TINTerval
5.12E–6
SENSe:WINDow
RECTangular
STEP:TOUTput
OFF
TRIGger:ACQuire:CURRent
0
TRIGger:ACQuire:CURRent:SLOPe
POSitive
TRIGger:ACQuire:SOURce
BUS
TRIGger:ACQuire:TOUTput
OFF
TRIGger:ACQuire:VOLTage
0
TRIGger:ACQuire:VOLTage:SLOPe
POSitive
TRIGger:ARB:SOURce
BUS
TRIGger:TRANsient:SOURce
BUS
VOLTage
0.1% of rating
VOLTage:LIMit
1% of rating
VOLTage:MODE
FIXed
VOLTage:PROTection
120% of rating
VOLTage:RESistance
0
VOLTage:RESistance:STATe
OFF
VOLTage:SLEW
MAX
VOLTage:SLEW:MAXimum
ON
VOLTage:TRIGgered
0.1% of rating
Non-Volatile Settings
The following table shows the as-shipped settings of the non-volatile parameters. These are not
affected by power cycling or *RST.
SCPI as-shipped settings
CALibrate:DATE
empty string
CALibrate:PASSword
0
DIGital:PIN<all>:FUNCtion
DINput
DIGital:PIN<all>:POLarity
POSitive