Supplemental Characteristics
Supplemental characteristics are not warranted but are descriptions of performance determined
either by design or by type testing. Supplemental characteristics are typical unless otherwise noted.
Characteristic
N69143A
N69145A
N69146A
N69172A
N69173A
Voltage programming
Range:
Resolution:
0.02 to 20.4 V
3.06 mV
0.08 to 81.6 V
12.8 mV
0.16 to 163.2V
25.6 mV
1 to 1020 V
160 mV
2 to 2040 V
320 mV
Current programming
Range:
Resolution:
0 to 816 A
248 mA
0 to 255 A
80 mA
0 to 127.5A
40 mA
0 to 61.2A
19.2 mA
0 to 30.6A
9.6 mA
Resistance programming
Range:
Resolution:
Accuracy:
0 to 0.049
Ω
0.4 µ
Ω
0.05% + 2 µ
Ω
0 to 0.625
Ω
4.8 µ
Ω
0.05% + 16 µ
Ω
0 to 2.5
Ω
19.6 µ
Ω
0.05% + 50 µ
Ω
0 to 69 Ω
0.55 mΩ
0.06% + 0.55 mΩ
0 to 277 Ω
2.2 mΩ
0.06% + 2.2 mΩ
Additional V-programming offset/
Ω
:
100 mV
30 mV
15 mV
N/A
N/A
Measurement range
Voltage:
Current:
0 to 25 V
-202.8 A to 2028 A
0 to 100 V
-63 A to 630 A
0 to 200 V
-31.5 A to 315 A
0 to 1200 V
-15.3 A to 153 A
0 to 2400 V
-7.65 A to 76.5 A
Program & measure tempCo/°C 1
Voltage:
Current:
0.0015% +80 µV
0.0075% +2.3mA
0.0015% +300µV
0.0025% +800µA
0.0015%+600µV
0.0025%+400µA
0.002%+7 mV
0.005%+240µA
0.002%+14 mV
0.005%+120µA
Output ripple & noise (20 Hz to 20 kHz)
CC rms:
200 mA
70 mA
50 mA
30 mA
15 mA
Common mode current
rms:
peak-to-peak:
2 mA
20 mA
2.5 mA
24 mA
3.5 mA
30 mA
2.5 mA
30 mA
2.5 mA
30 mA
Overvoltage protection
Maximum setting:
Accuracy:
Response time:2
24 V
0.02% + 2 mV
< 30 µs
96 V
0.02% + 8 mV
< 30 µs
192 V
0.02% + 16 mV
< 30 µs
1200 V
0.02% + 200 mV
< 30 µs
2400 V
0.02% + 200 mV
< 30 µs
Voltage up/down programming, comp 0 3
Rise/fall time 10% to 90% of step:
Settling time to 0.1% of step:
10 ms
50 ms
10 ms
50 ms
10 ms
50 ms
10 ms
50 ms
10 ms
50 ms
Voltage up/down programming, comp 1 3
Rise/fall time 10% to 90% of step:
Settling time to 0.1% of step:
20 ms
100 ms
20 ms
100 ms
20 ms
100 ms
20 ms
100 ms
20 ms
100 ms
Voltage up/down programming, comp 2 3
Rise/fall time 10% to 90% of step:
Settling time to 0.1% of step:
40 ms
200 ms
40 ms
200 ms
40 ms
200 ms
40 ms
200 ms
40 ms
200 ms
Current up/down programming, comp 0 4
Rise/fall time 10% to 90% of step:
Settling time to 1% of step:
2.5 ms
5 ms
2.5 ms
5 ms
2.5 ms
5 ms
2.5 ms
5 ms
2.5 ms
5 ms
Current up/down programming, comp 1 4
Rise/fall time 10% to 90% of step:
Settling time to 1% of step:
5 ms
10 ms
5 ms
10 ms
5 ms
10 ms
N/A
N/A