SENSe Subsystem
Sense commands control the current measurement ranges and window as well as the data
acquisition sequence.
SENSe:AHOur:RESet
SENSe:WHOur:RESet
Resets the amp-hour or watt-hour measurement to zero.
Parameter
Typical Return
(none)
(none)
Resets the amp-hour measurement: SENS:AHO:RES
Resets the watt-hour measurement: SENS:WHO:RES
SENSe:FUNCtion:CURRent 0|OFF|1|ON
SENSe:FUNCtion:CURRent?
SENSe:FUNCtion:VOLTage 0|OFF|1|ON
SENSe:FUNCtion:VOLTage?
Enables or disables current or voltage measurements.
Parameter
Typical Return
0|OFF|1|ON, *RST ON
0 or 1
Enables current measurements: SENS:FUNC:CURR ON
Disables voltage measurements: SENS:FUNC:VOLT OFF
SENSe:SWEep:NPLCycles <
value
>|MIN|MAX
SENSe:SWEep:NPLCycles? [MIN|MAX]
Sets the measurement time in number of power line cycles. Increasing the number of power line
cycles reduces the measurement noise on current and voltage measurements. Changing the NPLC
changes the number of points and time interval setting.
Parameter
Typical Return
0.0003072 to 1,258,290,000,000, *RST 1
<NPLC value>
Specifies 100 power line cycles: SENS:SWE:NPLC 100