:SOURce EXPRession<1-8>|NONE
Sets the on-couple signal source to an expression.
:DELay
:FALL <
value
>
Sets the output turn-off sequence delay.
:RISE <
value
>
Sets the output turn-on sequence delay.
:INHibit
:MODE LATChing|LIVE|OFF
Sets the operating mode of the remote inhibit digital pin.
:PON
:STATe RST|RCL0
Sets the output power-on state.
:PROTection
:CLEar
Resets the latched protection.
:MODE
Sets the turn-off behavior for all protection conditions.
:TEMPerature
:MARGin?
Returns the margin remaining before the over-tem-
perature trips.
:USER
[:STATe] 0|OFF|1|ON
Enables or disables the user-defined protection.
:SOURce EXPRession<1-8>|NONE
Sets the user-defined protection source to an expression.
:WDOG
[:STATe] 0|OFF|1|ON
Enables or disables the I/O watchdog timer.
:DELay <
value
>
Sets the watchdog delay time.
:RELay
:LOCK
[:STATe] 0|OFF|1|ON
Enables or disables the locked-closed state of the output
relays.
:POLarity NORMal|REVerse
Sets the polarity of the output relays.
:ENABle 0|OFF|1|ON
Enables or disables the polarity reversal function.
SENSe Subsystem
SENSe
:AHOur
:RESet
Resets the amp-hour or watt-hour measurement to zero.
:BBR
:PERiod <
value
>
Sets the recording period of the black box recorder in seconds.
:CURRent
[:DC]
:RANGe
[:UPPer] <
value
>
Selects a DC current measurement range.
:AUTO 0|OFF|1|ON
Enables or disables seamless measurement auto ranging.
:ELOG
:CURRent
[:DC]
:RANge
[:UPPer] <
value
>
Selects the Elog current measurement range.
:AUTO 0|OFF|1|ON
Enables or disables Elog seamless measurement autoranging.
1 Quick Reference
30
Keysight N6900/N7900 Series Operating and Service Guide
Summary of Contents for N6900 Series
Page 1: ...Keysight Advanced Power System N6900 N7900 Series Operating and Service Guide...
Page 2: ......
Page 63: ...1 kW Models Keysight N6900 N7900 Series Operating and Service Guide 63 1 Quick Reference...
Page 64: ...2 kW Models 1 Quick Reference 64 Keysight N6900 N7900 Series Operating and Service Guide...
Page 78: ...2 Installing the Instrument 78 Keysight N6900 N7900 Series Operating and Service Guide...