![Keysight Technologies N6900 Series Operating And Service Manual Download Page 169](http://html1.mh-extra.com/html/keysight-technologies/n6900-series/n6900-series_operating-and-service-manual_1962217169.webp)
Program pin 6 as the On Couple pin; program pin 7 as the Off Couple pin. This setting is saved in non
volatile memory.
Front Panel Menu Reference
SCPI Command
Select System\IO\DigPort\Pins
Select pin 6, then Function, then On Couple.
Select pin 7, then Function, then Off Couple.
To set pin 6 as the On Couple:
To set pin 7 as the Off Couple:
Enable the On Couple/Off Couple function. This setting is saved in non volatile memory.
Front Panel Menu Reference
SCPI Command
Select Output\Sequence\Couple
Check Enable to enable output coupling.
To enable output coupling:
You do not need to specify a Turn-on delay, Turn-off delay, or Delay offset.
Program the Output Voltage and Current
Refer to
and
for details.
In voltage priority mode:
l
Program the initial output voltage setting of each paralleled unit to the same value.
l
Set the current limit of each paralleled unit according to the following equations. This will allow all
units to share current until the total current limit point is reached, which is the sum total of all the
individual current limits.
For each 1kW unit: ICL_1kW =ICL_TOTAL / (NT+N2kW)*
For each 2kW unit: ICL_2kW =2(ICL_TOTAL) /( NT+N2kW)
where:
ICL_1kW is the current limit setting of the 1kW unit
ICL_2kW is the current limit setting of the 2kW unit
ICL_TOTAL is the sum total of all individual current limits
Keysight N6900/N7900 Series Operating and Service Guide
169
4 Using the Advanced Power System
Summary of Contents for N6900 Series
Page 1: ...Keysight Advanced Power System N6900 N7900 Series Operating and Service Guide...
Page 2: ......
Page 63: ...1 kW Models Keysight N6900 N7900 Series Operating and Service Guide 63 1 Quick Reference...
Page 64: ...2 kW Models 1 Quick Reference 64 Keysight N6900 N7900 Series Operating and Service Guide...
Page 78: ...2 Installing the Instrument 78 Keysight N6900 N7900 Series Operating and Service Guide...