7-48 Keysight N5247B Service Guide
Repair and Replacement Procedures
Removing and Replacing the A37 Reference Mixer Switch
7-
Removing and Replacing the A37 Reference Mixer Switch
Tools Required
— T-10 TORX driver (set to 9 in-lb)
— T-20 TORX driver (set to 21 in-lb)
— 5/16 inch open-end torque wrench (set to 10 in-lb)
— ESD grounding wrist strap
Removal Procedure
Refer to
for this procedure.
1.
Disconnect the power cord.
2.
Remove the outer cover. Refer to
“Removing the Covers” on page 7-6
3.
Position the analyzer bottom side up.
4.
Disconnect four semirigid cables (item
) from the A37 reference mixer
switch.
5.
Remove two screws (item
) that secure the A37 reference mixer switch
to the side of the test set deck.
6.
Move the disconnected semirigid cables out of the way and lift the A37
reference mixer switch and mounting bracket out of the analyzer. It may
be necessary to loosen the connector at the other end of some of the
semirigid cables to allow them to be moved enough.
7.
Disconnect the wire harness cable (item
) from the A37 reference mixer
switch.
8.
Remove two screws (item
) that attach the A37 reference mixer switch
to its mounting bracket.
Replacement Procedure
1.
Reverse the order of the removal procedure.
1. The A26 splitter (5067-4086) and
N5247-20111, N5245-20022, N5245-20023, and N5247-20110 cables are only used
with a legacy HMA26.5 p/n: 5087-7765. The N5240-20125, N5247-20184 and N5247-20185 cables are used only with the
new N5240-60101 HMA-26.5.
If you are unclear which HMA26.5 assembly your PNA has installed, refer to Chap-
and for details on A26 splitter and cabling, refer to your
option-model in Chapter 6
“2-Port Configurations, Serial Number Prefixes <6021” on page 6-31
Configuration, Serial Number Prefixes <6021” on page 6-84
.
Be careful not to damage the center pins of the semirigid cables. Some
flexing of the cables is necessary to remove the assembly. However, do not
over-bend the semirigid cables.
Summary of Contents for N5247B
Page 10: ...10 Keysight N5247B Service Guide Contents ...
Page 96: ...3 66 Keysight N5247B Service Guide Tests and Adjustments Adjustments 3 ...
Page 157: ...Keysight N5247B Service Guide 4 61 Troubleshooting This page left intentionally blank ...
Page 268: ...6 30 Keysight N5247B Service Guide Replaceable Parts Replaceable Parts Listings 6 ...
Page 270: ...6 32 Keysight N5247B Service Guide Replaceable Parts Replaceable Parts Listings 6 ...
Page 373: ...Keysight N5247B Service Guide 6 135 Replaceable Parts Replaceable Parts Listings ...
Page 426: ...6 188 Keysight N5247B Service Guide Replaceable Parts Replaceable Parts Listings 6 ...
Page 565: ...Installation Note Xxxxx xxxxx 3 ...