Keysight Technologies N5191A Firmware Upgrade Manual Download Page 7

Firmware Upgrade Guide N5191-90023

7

Firmware Upgrade Guide

Step 3. Connect the Signal Generator to the PC

Using LAN

Connect the signal generator to the PC:
Either

— use a 100 Base-T LAN cable to connect the signal generator to the PC,

or

— connect both the PC and the signal generator to the LAN using 100 Base-T LAN cables.
There are numerous ways to configure the signal generator to connect to the LAN. Refer to:

— Keysight MXG FAQ’s “How do I connect the Keysight MXG Signal Generator to a PC using 

LAN?”.

— Keysight Technologies IO Libraries USB/LAN/GPIB Interfaces Connectivity Guide (E2094–

90009).

— Keysight X-Series 

Programming Guide

 or, 

http://www.keysight.com/find/uxg

Depending on the signal generator's current LAN settings and which procedure you choose, the 

signal generator's LAN settings may be changed. Since these settings are persistent (retained 

through presets and power cycles) it is recommended that you record the current LAN settings so 

you can restore them back to their original settings after upgrading the firmware. Information on 

the LAN softkeys is provided in key 

Help

 of the instrument. See also the 

User’s Guide.

Using GPIB

1.

Connect a GPIB cable between the PC and the signal generator.

2.

Set the GPIB address: 
Press 

Utility

 > 

I/O Config

 > 

GPIB Setup

 >

 GPIB Address

 > 

19

The signal generator’s GPIB address is set to 19 at the factory. The acceptable range of 

addresses is 0 through 30. Once initialized, the state of the GPIB address is not affected by a 

signal generator preset or by a power cycle. Other instruments on the GPIB cannot use the 

same address as the signal generator.

Using USB

Connect a USB cable between the PC and the signal generator’s rear panel Micro USB connector.
If the “Found New Hardware” wizard activates, select 

Install the Software Automatically

.

If there is more than one signal generator on the same bus whose GPIB address is 19, turn the 

power off to the instrument(s) or change the address of the signal generator of interest.

Summary of Contents for N5191A

Page 1: ...For the latest revision of this installation note go to the following website http www keysight com find uxg Keysight Technologies N5191A 93A Agile Signal Generators Firmware Upgrade Guide...

Page 2: ...to the implied warranties of merchantability and fitness for a particular purpose Keysight Technologies shall not be liable for errors contained herein or for incidental or consequential damages in c...

Page 3: ...re Upgrade Guide Product Affected N5191A 93A Serial Numbers All Options All To Be Performed By X Keysight Technologies Service Center X Personnel Qualified by Keysight Technologies X Customer Estimate...

Page 4: ...operation of the signal generator If you are not comfortable with using the signal generator s menus and with entering parameter values refer to the instrument s User s Guide and familiarize yourself...

Page 5: ...4 01 or later Netscape Navigator 4 0 or later If using GPIB an installed and configured GPIB IO interface card and a GPIB cable either the Keysight or National Instruments I O Libraries If using LAN...

Page 6: ...roblem 1 Turn on power to the signal generator and let it warm up for at least five minutes 2 Check to see if the ERR annunciator is on If the ERR annunciator is off the signal generator s functionali...

Page 7: ...it is recommended that you record the current LAN settings so you can restore them back to their original settings after upgrading the firmware Information on the LAN softkeys is provided in key Help...

Page 8: ...see page 9 4 After the upgrade completes press the signal generator s Local hardkey to return front panel control 5 Run the signal generator s functionality check see page 6 If the upgrade is interru...

Page 9: ...Firmware Upgrade Guide N5191 90023 9 Firmware Upgrade Guide Running the Upgrade Assistant...

Page 10: ...10 Firmware Upgrade Guide N5191 90023 Firmware Upgrade Guide...

Page 11: ...e regarding the signal generator s problem 2 Call the phone number listed on the Internet http www keysight com find assist that is specific to your geographic location If you do not have access to th...

Page 12: ...This information is subject to change without notice Keysight Technologies 2018 Edition 1 July 2018 N5191 90023 www keysight com...

Reviews: