226
Keysight M8070A Programming Guide
5
SCPI Command Reference
:OUTPut:TRIGger:MODE[?]
Syntax
:OUTPut:TRIGger:MODE ‘identifier’, <CLOCk|SEQuencer>
:OUTPut:TRIGger:MODE? ‘identifier’
Input
Parameters
‘identifier’: 'M1.TrigOut'
<CLOCk|SEQuencer>: Set the operating mode of the trigger out.
Return Range
CLOC|SEQ
Description
This command sets the operating mode of the trigger out (TRIG OUT)
either to subrate clock or sequencer controlled mode.
This SCPI is applicable for M8041A and M8045A.
Example
:OUTP:TRIG:MODE ‘M1.TrigOut’, CLOC
:OUTPut:TRIGger:DIVider[?]
Syntax
:OUTPut:TRIGger:DIVider ‘identifier’, <NRf>
:OUTPut:TRIGger:DIVider? ‘identifier’
Input
Parameters
‘identifier’: 'M1.TrigOut'
<NRf>: Set the divider factor for the trigger out.
Return Range
2 to 65535
Description
This command sets the divider factor of the trigger out when the subrate
clock operating mode is selected.
This SCPI is applicable for M8041A and M8045A.
Example
:OUTP:TRIG:DIV ‘M1.TrigOut’, 8