60
6000L Series Oscilloscopes Service Guide
4
Troubleshooting
Table 12
Equipment Required to Troubleshoot the Oscilloscope
To check out the oscilloscope
1
Disconnect any external cables from the front panel.
2
Disconnect the power cord, then remove the cabinet following the instructions
on
for Keysight 6000L Series models.
3
Connect the power cord to the rear of the oscilloscope, then to a suitable ac
voltage source.
The oscilloscope power supply automatically adjusts for input line voltages in
the range of 100 to 240 VAC. Ensure that you have the correct line cord. The
power cord provided is matched to the country of origin.
T
Equipment
Critical Specifications
Recommended Model/Part
Digital multimeter
Accuracy ±0.05,% 1 mV resolution
Keysight 34401A
Oscilloscope
Capable of measuring
≥
500 MHz signal. 1
M
Ω
input impedance.
Keysight
DSO6102A, MSO6102A,
DSO6102A, or MSO6104A
CAUTION
USE AN EXTERNAL FAN TO AVOID OVERHEATING COMPONENTS !
When you remove the oscilloscope cover and main shield, use an external fan to provide continuous air
flow over the heat sinks. Air flow over the heat sinks is reduced when the cover and main shield are
removed, which leads to higher than normal operating temperatures. Have the fan blow air across the
system board where the heat sinks are located. Otherwise, damage to the components can occur.
WARNING
HAZARDOUS VOLTAGES EXIST — HIGH VOLTAGE IS PRESENT ON DSO6000L SERIES POWER SUPPLY
HEAT SINKS !
The power supply heat sinks of the 6000L Series oscilloscopes are at a high potential. This presents an
electric shock hazard. Protect yourself from electric shock by keeping this area covered or by not coming
in contact with the heat sinks when the power cord is attached to the oscilloscope!
CAUTION
Use
only
the power cord that came with the oscilloscope
The power cord provided is matched to the country of origin of the order.
Summary of Contents for InfiniVision 6000L Series
Page 1: ...Keysight InfiniVision 6000L Series Oscilloscopes Service Guide...
Page 8: ...8 6000L Series Oscilloscopes Service Guide Contents...
Page 10: ...10 6000L Series Oscilloscopes Service Guide Figures...
Page 12: ...12 6000L Series Oscilloscopes Service Guide Tables...
Page 48: ...48 6000L Series Oscilloscopes Service Guide 2 Testing Performance...
Page 54: ...54 6000L Series Oscilloscopes Service Guide 3 Calibrating and Adjusting...
Page 86: ...86 6000L Series Oscilloscopes Service Guide 5 Replacing 6000L Assemblies...
Page 94: ...94 6000L Series Oscilloscopes Service Guide 6 Replaceable Parts...