1256
Keysight InfiniiVision M9241/42/43A PXIe Oscilloscopes SCPI Programmer's Guide
34
:WMEMory<r> Commands
:WMEMory<r>:SAVE
Command Syntax
:WMEMory<r>:SAVE <source>
<r> ::= 1 to (# ref waveforms) in NR1 format
<source> ::= {CHANnel<n> | FUNCtion<m> | MATH<m>}
<n> ::= 1 to (# analog channels) in NR1 format
<m> ::= 1 to (# math functions) in NR1 format
The :WMEMory<r>:SAVE command copies the analog channel or math function
waveform to the specified reference waveform location.
Reference waveforms are limited to 64K points. If necessary, decimation of the
source waveform will occur during the save.
See Also
•
, “:WMEMory<r> Commands,” starting on page 1251
•
NOTE
Math functions whose x-axis is not frequency can be saved as reference waveforms.
NOTE
:WMEMory<r>:SAVE is an overlapped command (see