MIL-STD-1553/ARINC 429 Triggering and Serial Decode
27
Keysight InfiniiVision 3000 X-Series Oscilloscopes User's Guide
405
Searching for MIL-STD-1553 Data in the Lister
The oscilloscope's search capability lets you search for (and mark) certain types of
MIL-STD-1553 data in the Lister. You can use the
[Navigate]
key and controls to
navigate through the marked rows.
1
With MIL-STD-1553 selected as the serial decode mode, press
[Search]
.
2
In the Search Menu, press the
Search
softkey; then, turn the Entry knob to select
the serial slot (Serial 1 or Serial 2) on which the MIL-STD-1553 signal is being
decoded.
3
Press
Search
; then, select from these options:
•
Data Word Start
— finds the start of a Data word (at the end of a valid Data
Sync pulse).
•
Command/Status Word Start
— finds the start of Command/Status word (at the
end of a valid C/S Sync pulse).
•
Remote Terminal Address
— finds the Command/Status word whose RTA
matches the specified value. The value is specified in hex.
When this option is selected, the
RTA
softkey becomes available and lets you
select the hex Remote Terminal Address value to find.
•
Remote Terminal A 11 Bits
— finds the RTA and the remaining 11 bits
that match the specified criteria.
When this option is selected, these softkeys become available:
•
The
RTA
softkey lets you select the hex Remote Terminal Address value.
•
The
Bit Time
softkey lets you select the bit time position.
•
The
0 1 X
softkey lets you set the bit time position value as a 1, 0, or X
(don't care).
•
Parity Error
— finds (odd) parity bits that are incorrect for the data in the word.
•
Sync Error
— finds invalid Sync pulses.
•
Manchester Error
— finds Manchester encoding errors.
For more information on searching data, see
For more information on using the
[Navigate]
key and controls, see
Summary of Contents for InfiniiVision 3000 X Series
Page 1: ...Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide...
Page 8: ...8 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide...
Page 24: ...24 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide...
Page 48: ...48 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 1 Getting Started...
Page 62: ...62 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Page 72: ...72 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 3 Vertical Controls...
Page 122: ...122 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Page 128: ...128 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Page 134: ...134 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 8 Display Settings...
Page 182: ...182 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling...
Page 200: ...200 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 12 Acquisition Control...
Page 210: ...210 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 13 Cursors...
Page 252: ...252 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 15 Mask Testing...
Page 256: ...256 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Page 290: ...290 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 19 Print Screens...
Page 324: ...324 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 21 Web Interface...
Page 344: ...344 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 22 Reference...