Waveform Generator
Pressing a signal parameter softkey can open a menu for selecting the type of
adjustment. For example, you can choose to enter amplitude and offset values,
or you can choose to enter high-level and low-level values. Or, you can choose
to enter frequency values or period values. Keep pressing the softkey to select
the type of adjustment. Turn the Entry knob to adjust the value.
Notice that you can select between coarse and fine adjustments for frequency,
period, and width. Also, pushing the Entry knob is a quick way to toggle
between coarse and fine adjustments.
The
Settings
softkey opens the Waveform Generator Settings Menu which lets you
make other settings related to the waveform generator.
See:
•
"To output the waveform generator sync pulse"
•
"To specify the expected output load"
•
"To use waveform generator logic presets"
•
"To add noise to the waveform generator output"
Exponential
Fall
Use the
Frequency/Frequency Fine/Period/Period
Fine
,
Amplitude
/
High-Level
, and
Offset
/
Low-Level
softkeys to set the exponential fall signal
parameters.
100 mHz to
5 MHz
20 mVpp to
5 Vpp
±2.50 V
Cardiac
Use the
Frequency/Frequency Fine/Period/Period
Fine
,
Amplitude
, and
Offset
softkeys to set the
cardiac signal parameters.
100 mHz to
200 kHz
20 mVpp to
5 Vpp
±1.25 V
Gaussian Pulse
Use the
Frequency/Frequency Fine/Period/Period
Fine
,
Amplitude
, and
Offset
softkeys to set the
gaussian pulse signal parameters.
100 mHz to
5 MHz
20 mVpp to
4 Vpp
±1.25 V
1
When the output load is 50
Ω
, these values are halved.
Waveform
Type
Characteristics
Frequency
Range
Max.
Amplitude
(High-Z)
1
Offset
(High-Z)
1
Summary of Contents for InfiniiVision 3000 X Series
Page 1: ...Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide...
Page 8: ...8 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide...
Page 24: ...24 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide...
Page 48: ...48 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 1 Getting Started...
Page 62: ...62 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Page 72: ...72 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 3 Vertical Controls...
Page 122: ...122 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Page 128: ...128 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Page 134: ...134 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 8 Display Settings...
Page 182: ...182 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling...
Page 200: ...200 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 12 Acquisition Control...
Page 210: ...210 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 13 Cursors...
Page 252: ...252 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 15 Mask Testing...
Page 256: ...256 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Page 290: ...290 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 19 Print Screens...
Page 324: ...324 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 21 Web Interface...
Page 344: ...344 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 22 Reference...