Data Analysis Features
All about Markers
604 Keysight N9927-90001 User’s Guide
There are more trace formats available than marker formats. To display marker readouts in more
formats than are shown here, change the trace format, then select
Default
. Learn how to change
— For
TDR (CAT) Mode
, choose from
Default
and
Z Mag
.
Searching with Markers
Marker Searches are used to move markers to locations on the trace which exhibits the
characteristics of the search criteria. Learn ‘What is a Peak” in
“What Is a ‘Peak’” on page 609
.
How to Search with Markers
The following menu structure applies to NA Mode. Keystrokes will be slightly different for CAT, Pulse
Measurements, and SA Modes.
— Activate the marker to be used for the search (NOT necessary with Bandwidth search.)
— Then press
Mkr ->/Tools
.
— Then choose one of the following:
—
Tracking ON OFF
(NA Mode ONLY)
——
ON
causes the active marker to search for the specified criteria with each new
sweep. Search criteria can include: Target, Bandwidth, Peak, Min. The searches
begin with the first sweep after Tracking is turned ON, based on the current search
type.
Trk
appears next to the marker number.
——
OFF
causes a new marker search only when the search feature is re-executed.
—
Peak
Moves the active marker to the HIGHEST amplitude data point of the trace. Peak
Excursion and Peak Threshold value is ignored. In SA Mode, the LO feed-through signal (0
Hz) is also ignored.
—
Next Peak
Moves the active marker to the next highest amplitude data point of the trace.
Peak Excursion value is ignored.
—
Mkr -> Center
Moves the current active selected marker to the center frequency for the
current frequency range displayed.
—
Mkr -> RefLev
Moves the current active marker to the acquisition.
—
Minimum
(Not available in DTF, RTSA, SA, or I/Q Analyzer) Moves the active marker to
the LOWEST amplitude data point of the trace.
—
Min Search
(I/Q Analyzer, RTSA, and SA modes Only) Moves the active marker to the
LOWEST amplitude data point of the trace. If a marker is turned off, it is turned on before
the minimum search is performed.
—
Target
(NA Mode and Pulse Measurements ONLY) Enter the Target value. The marker
moves to the first occurrence of the Target value to the right of its current position. The
FieldFox interpolates between measured data points to find the exact Target value to two
decimal points. The interpolated X-axis value is displayed in the marker readout or marker
table. Subsequent presses of the Target softkey cause the marker to move to the right to
Summary of Contents for FieldFox A Series
Page 6: ...6...
Page 596: ...596 Keysight N9927 90001 User s Guide Noise Figure Mode Option 356 CPU2 Only Troubleshooting...
Page 622: ...Data Analysis Features All about Scale Settings 622 Keysight N9927 90001 User s Guide...
Page 668: ...668 Keysight N9927 90001 User s Guide System Settings Service Diagnostics...
Page 718: ...718 Keysight N9927 90001 User s Guide Specifications Data Sheet...
Page 721: ...721 Keysight Handheld Analyzers N99xxA User s Guide D Korean Battery Safety Translation...
Page 722: ...722 Keysight N9927 90001 User s Guide Korean Battery Safety Translation...
Page 723: ...Keysight N9927 90001 User s Guide 723 Korean Battery Safety Translation...
Page 724: ...724 Keysight N9927 90001 User s Guide Korean Battery Safety Translation...
Page 725: ...Keysight N9927 90001 User s Guide 725 Korean Battery Safety Translation...
Page 726: ...726 Keysight N9927 90001 User s Guide Korean Battery Safety Translation...
Page 727: ...Keysight N9927 90001 User s Guide 727 Korean Battery Safety Translation...
Page 728: ...728 Keysight N9927 90001 User s Guide Korean Battery Safety Translation...
Page 729: ...Keysight N9927 90001 User s Guide 729 Korean Battery Safety Translation...
Page 730: ...730 Keysight N9927 90001 User s Guide Korean Battery Safety Translation...
Page 731: ...731 Keysight Handheld Analyzers N99xxA User s Guide E Russian Battery Safety Translation...
Page 732: ...732 Keysight N9927 90001 User s Guide Russian Battery Safety Translation...
Page 733: ...Keysight N9927 90001 User s Guide 733 Russian Battery Safety Translation N9927 90001...
Page 734: ...734 Keysight N9927 90001 User s Guide Russian Battery Safety Translation N9927 90001...
Page 735: ...Keysight N9927 90001 User s Guide 735 Russian Battery Safety Translation N9927 90001...
Page 736: ...736 Keysight N9927 90001 User s Guide Russian Battery Safety Translation N9927 90001...
Page 737: ...Keysight N9927 90001 User s Guide 737 Russian Battery Safety Translation N9927 90001...
Page 738: ...738 Keysight N9927 90001 User s Guide Russian Battery Safety Translation N9927 90001...
Page 739: ...Keysight N9927 90001 User s Guide 739 Russian Battery Safety Translation N9927 90001...
Page 740: ...740 Keysight N9927 90001 User s Guide Russian Battery Safety Translation N9927 90001...
Page 741: ...Keysight N9927 90001 User s Guide 741 Russian Battery Safety Translation N9927 90001...
Page 742: ...742 Keysight N9927 90001 User s Guide Russian Battery Safety Translation...
Page 744: ...744 Keysight N9927 90001 User s Guide Keysight Software End User Licensing Agreement EULA...
Page 745: ...Keysight N9927 90001 User s Guide 745 Keysight Software End User Licensing Agreement EULA...
Page 746: ...746 Keysight N9927 90001 User s Guide Keysight Software End User Licensing Agreement EULA...
Page 754: ...Keysight N9927 90001 User s Guide Index...
Page 755: ......