Using the E6960-66600 Frequency Divider Board
D
Keysight E6960A User Guide and Method of Implementation
67
Configure the test setup as shown below.
Figure D-3
Test Setup for 10 MHz Frequency Reference
Frequency Divider Board Test Setup
1
Connect CH1 SMA connector to the Device Under Test (DUT).
2
Use BNC to BNC cables to connect both J400 and J403 BNC connectors to
the oscilloscope and the AWG 10 MHz In.
3
Select 4.2 Vpp output voltage by shorting Pin1 and Pin2 of J100 with jumper.
Remark: 10MHz ref input amplitude and frequency specification for every
oscilloscope might be different. Please ensure the oscilloscope that you use
meets the specifications. In the event it doesn't, an attenuator might be
required.
4
Select Normal Running mode by switching switch A1 to OFF.
5
Select Frequency Tracking mode by switching switch A2 to OFF.
LAN or USB cable
BNC to BNC Cables
N5395A Ethernet Transmitter Test Fixture
RJ45 CAT5e LAN Cable
BNC to
SMA
Cables
D+
D-
10MHz Ref in to oscilloscope and AWG Master BNC to BNC cables
Frequency
Divider
Board
TX_CLK
SMA to SMA
cable
DUT
SMA
to
SMA
Cables