CAN/LIN Triggering and Serial Decode
5
Press
Source
; then, select the channel for the CAN signal.
The label for the CAN source channel is automatically set.
6
Press the
Threshold
softkey; then, turn the Entry knob to select the CAN signal
threshold voltage level.
The threshold voltage level is used in decoding, and it will become the trigger
level when the trigger type is set to the selected serial decode slot.
7
Press the
Baud
softkey; then, turn the Entry knob to select the baud rate that
matches match your CAN bus signal.
The CAN baud rate can be set to predefined baud rates from 10 kb/s up to
5 Mb/s or a user-defined baud rate from 10.0 kb/s to 4 Mb/s in increments of
100 b/s. Fractional user-defined baud rates between 4 Mb/s and 5 Mb/s are
not allowed.
The default baud rate is 125 kb/s
If none of the pre-defined selections match your CAN bus signal, select
User
Defined
; then, press the
User Baud
softkey and turn the Entry knob to enter the
baud rate.
8
Press the
Sample Point
softkey; then, turn the Entry knob to select the point
between phase segments 1 and 2 where the state of the bus is measured. This
controls the point within the bit's time where the bit value is captured.
9
Press the
Signal
softkey and select the type and polarity of the CAN signal. This
also automatically sets the channel label for the source channel.
•
CAN_H
— The actual CAN_H differential bus.
60%
70%
80%
Sample Point
One Bit
Summary of Contents for DSO-X 2014A
Page 1: ...Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Page 8: ...8 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Page 60: ...60 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Page 68: ...68 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 3 Vertical Controls...
Page 118: ...118 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Page 124: ...124 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Page 130: ...130 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 8 Display Settings...
Page 168: ...168 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 10 Triggers...
Page 176: ...176 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling...
Page 202: ...202 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 13 Cursors...
Page 226: ...226 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 14 Measurements...
Page 240: ...240 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 15 Mask Testing...
Page 244: ...244 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Page 256: ...256 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 17 Waveform Generator...
Page 274: ...274 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 19 Print Screens...
Page 308: ...308 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 21 Web Interface...
Page 326: ...326 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 22 Reference...