Keysight D9020DDRC DDR2(+LP) Compliance Test Application
Compliance Testing Methods of Implementation
4
Single-Ended Signals AC
Input Parameters Tests
Probing for Single-Ended Signals AC Input Parameters Tests / 56
VIH(AC) Test for DQ, DM - Test Method of Implementation / 58
VIH(AC) Test for DQS - Test Method of Implementation / 60
VIH(AC) Test for Address, Control - Test Method of Implementation / 62
VIH(DC) Test for DQ, DM - Test Method of Implementation / 64
VIH(DC) Test for DQS - Test Method of Implementation / 66
VIH(DC) Test for Address, Control - Test Method of Implementation / 68
VIL(AC) Test for DQ, DM - Test Method of Implementation / 70
VIL(AC) Test for DQS - Test Method of Implementation / 72
VIL(AC) Test for Address, Control - Test Method of Implementation / 74
VIL(DC) Test for DQ, DM - Test Method of Implementation / 76
VIL(DC) Test for DQS - Test Method of Implementation / 78
VIL(DC) Test for Address, Control - Test Method of Implementation / 80
SlewR Test for DQ, DM, DQS - Test Method of Implementation / 82
SlewR Test for Address, Control, Clock - Test Method of Implementation / 84
SlewF Test for DQ, DM, DQS - Test Method of Implementation / 86
SlewF Test for Address, Control, Clock - Test Method of Implementation / 88
SRQseR (40ohm) - Test Method of Implementation / 90
SRQseF (40ohm) - Test Method of Implementation / 92
SRQseR (60ohm) - Test Method of Implementation / 93
SRQseF (60ohm) - Test Method of Implementation / 94
VOH(AC) - Test Method of Implementation / 95
VOH(DC) - Test Method of Implementation / 96
VOL(AC) - Test Method of Implementation / 97
VOL(DC) - Test Method of Implementation / 98
This section provides the Methods of Implementation (MOIs) for Single-Ended Signals AC Input tests
using a Keysight 80000B or 90000A Series Infiniium oscilloscope, recommended InfiniiMax 116xA or
113xA probe amplifiers, differential solder-in probe head and the DDR2(+LP) Compliance
Test Application.
Summary of Contents for D9020DDRC
Page 1: ...Keysight D9020DDRC DDR2 LP Compliance Test Application Methods of Implementation ...
Page 10: ...10 DDR2 LP Compliance Testing Methods of Implementation ...
Page 46: ...2 Preparing to Take Measurements 30 DDR2 LP Compliance Testing Methods of Implementation ...
Page 70: ...3 Measurement Clock Tests 54 DDR2 LP Compliance Testing Methods of Implementation ...
Page 224: ...14 Clock Timing CT Tests 208 DDR2 LP Compliance Testing Methods of Implementation ...
Page 270: ...15 Data Strobe Timing DST Tests 254 DDR2 LP Compliance Testing Methods of Implementation ...