Step 3: Install the Software

System Requirements

Item

Requirements

Operating sys-

tem

Windows XP SP3

Windows Vista®

SP1 and SP2,

Windows 7®

(32 or 64-bit), All versions.

Linux

kernel 2.6 or higher (32 or 64-bit),

Debian 6.0, CentOS 5

Processor

speed

600 MHz or higher required

800 MHz recommended

1 GHz 32-bit (x86), 1 GHz 64-bit

(x64), no support for Itanium64

As per the minimum requirements

of the chosen distribution.

Available mem-

ory

256 MB minimum,(1 GB or

greater recommended

1 GB minimum

As per the minimum requirements

of the chosen distribution.

Available disk

space

1

1.5 GB available hard disk space, includes:

l

1 GB available for Microsoft .NET Framework 3.5 SP1

2

l

100 MB for Agilent IO Libraries Suite

100 MB

Video

Super VGA (800x600) 256 col-

ors or more

Support for DirectX 9 graphics with

128 MB graphics memory

recommended (Super VGA

graphics is supported)

Does not require graphics

(headless system).

X Windows with 1280x1024

recommended for SFP

Browser

Microsoft Internet Explorer 6.0

or higher

Microsoft Internet Explorer 7.0 or

higher

Distribution supplied browser.

1 Note: Because of the installation procedure, less disk space may be required for operation than is required for installation. The amount of space

listed above is required for installation.

2 Note: .NET Framework Runtime Components are installed by default with Windows Vista. Therefore, you may not need this amount of available

disk space.

Item

Module &

 

Chassis Requirements

Chassis

PXIe chassis

PXI System /

Host Controller

A remote PC

 

Host or PXI Express embedded controller is required

Embedded

Controller

An embedded PC host controller must meet the following requirements:

l

PXIe System Controller (in PXIe chassis)

l

Utilize a 2x8, 4x4, 1x8, or 1x4 PXIe System slot link configuration

l

Run one of the above operating systems

Remote

Controller

Agilent M9021A PXIe System Interface x8 with one of the following PC interface options:

l

Agilent M9045A PCIe ExpressCard Adaptor x1, with cable (for laptops)

l

Agilent M9047A PCIe Desktop Adaptor x8, with cable (for desktop PCs)

Or an equivalent remote controller connected to a PC running one of the above operating systems.

Power up the Controller

If you are using a remote controller, power up the host computer.

If you are using an embedded controller, complete the following steps:

1. Install the embedded controller module into the compatible chassis (Agilent M9018A chassis recommended).

2. Connect peripherals (mouse, keyboard, monitor).

3. Power up the chassis.

10

M9202A PXI Express 12-bit Wideband IF Digitizer Startup Guide

Summary of Contents for Agilent Technologies PXI Express M9202A

Page 1: ...bit Wideband IF Digitizer M9202A Startup Guide NOTICE This document contains references to Agilent Technologies Agilent s former Test and Measurement business has become Keysight Technologies For more...

Page 2: ...or contract clause Use duplication or disclosure of Software is subject to Agilent Technologies standard commercial license terms and non DOD Departments and Agencies of the U S Government will recei...

Page 3: ...the voltage being measured The instrument and accessories must be used in accordance with its specifications and operating instructions or the safety of the equipment may be impaired Do not exceed th...

Page 4: ...nt means caution risk of danger You should refer to the operating instructions located in the user documen tation in all cases where the symbol is marked on the instrument This symbol indicates the ti...

Page 5: ...anel Connectors 13 Front Panel LED 13 Step 5 Verify Operation of the M9202A Module 14 Conducting a Self Test 15 Conduct M9202A Operational check optional 16 Requirements for Verification 16 Required H...

Page 6: ...Documentation Map 6 M9202A PXI Express 12 bit Wideband IF Digitizer Startup Guide...

Page 7: ...elect Technical Support Manuals l Help system for the Soft Front Panel l Help systems for the device drivers IVI C and IVI COM and LabVIEW G l Specifications Data Sheet Follow the Startup Sequence Thi...

Page 8: ...spect for damage After unpacking the module carefully inspect it for any shipping damage Report any damage to the shipping agent immediately as such damage is not covered by the warranty Warranty info...

Page 9: ...instrument or prevent it from moving in the shipping container Styrene pellets can also cause equipment damage by generating static electricity or by lodging in fan motors If any correspondence is req...

Page 10: ...r operation than is required for installation The amount of space listed above is required for installation 2 Note NET Framework Runtime Components are installed by default with Windows Vista Therefor...

Page 11: ...llowing l Agilent IO Library Suite IOLS which includes the Agilent Connection Expert This software must be installed first Version 16 2 or newer of the Agilent IO Libraries Suite is required l Soft Fr...

Page 12: ...e triangle symbol 5 Install the module into the appropriate slot of the chassis by placing the module card edges into the front mod ule guides top and bottom Ensure that the ejector handle is pushed d...

Page 13: ...t This input is AC cou pled and 50 terminated The recommended signal level is 1 V pk pk 4 dBm The clock signal frequency should be half of the desired sampling frequency TRG OUT This MMCX female conne...

Page 14: ...202 module is recognized 3 Select the M9202A module and check that the correct Model Name appears in the Instrument Properties 4 Select the Installed Software tab and review the configuration data as...

Page 15: ...e with the processor controlling it When the SFP is launched it will initiate a self calibration which takes a little over 1 minute Verify that no error is shown in the lower left hand log area The im...

Page 16: ...or 1x BNC MMCX cable 50 Coaxial 100 cm Operational Verification Procedure Do not exceed the maximum power level to the INPUT connector 0 5 W 1 Launch the soft front panel SFP The calibration must succ...

Page 17: ...cilloscope 3 If the problem occurs during Operational Verification disconnect the input signal and note the status of the LED on the front panel it should be GREEN Reconnect the signal and select the...

Page 18: ...ers Manufacturers Group PCIe and PCI EXPRESS are registered trademarks and or service marks of PC SIG Microsoft Windows VisualStudio VisualC VisualC and VisualBasic are either registered trademark or...

Reviews: