Technical data 

 

General  

 

Number of keys 

10… 2000 for one control panel  

Number of cabinets 

Up to 20 

 

 

Power  

 

Nominal input voltage range 

100 V AC ... 240 V AC 

AC input voltage range 

85 V AC ... 264 V AC 

AC frequency range 

45 Hz ... 65 Hz 

Choice of suitable entry fuses  

6 A ... 16 A 

Power consumption 

60 Wt max 

Internal voltage 

24V/14V 

Battery   

6V 4.5Ач Fiamm FG10451 2 pcs 

Operation from battery  

Up to 20 h 

 

 

Ambient condition 

 

Ambient temperature 

-30 °C ... 60 °C 

Max. permissible relative humidity 

≤95%  
(at 25 °C, no condensation) 

 

 

Housing 

 

Steel  
With stainless steel insertion 

2 mm 

IP protection  

IP 20 

Dimension W/H/D  5 mod cabinet 
Dimension W/H/D  10 mod cabinet 

430 mm x 742 mm x 132 mm 
715 mm x 742 mm x 132 mm

 

Control panel Dimension W/H/D   

350 mm х 193 mm х 38 mm 

Color dark model 
Color light model 

dark silver 5359AO445 
RAL7038

 

 

 

Emergency release mode  

 

Abloy  mechanical  (HSS)  lock  to  unlock  main 
and internal doors. 

Included  

 

 

Package  

 

Weight 5 mod cabinet  
Weight 10 mod cabinet 

35 kg 
50 kg 

Package size 5 mod cabinet W/H/D   
Package size 10 mod cabinet W/H/D   

550 mm х 880 mm х 250 mm 
820 mm х 880 mm х 250 mm 

 

 

Security  

 

Door contract  

Biased  reed  are  resistant  to  defeat  by 
external magnets

 

Alarm outputs  

 

 

Outputs 

 

Outputs (free programmable) 

4 outputs 250V 0.1A 30Om 

Summary of Contents for Solid Door

Page 1: ...1 4 Add On cabinet connection 4 1 5 Connection of control signals 6 1 6 Card Reader replacement 7 1 7 Mains and Ground connection 7 1 8 Battery connection 8 1 9 Adding keys 8 1 10 Use of sealed key b...

Page 2: ...carry out 50 kg of the cabinet 1 2 Control panel installation The control panel is mounted by means of one of the two brackets supplied with the device One bracket is designed to secure the control p...

Page 3: ...f fastening which makes it possible to precisely adjust the position of the panel push it close or slightly push the panel away from the housing The bracket for horizontal fastening to the right of th...

Page 4: ...1 4 Add On cabinet connection It is possible to connect several Add on cabinets to the one control panel Add On cabinet connection...

Page 5: ...Fig 1 Attention It is important to use the insulating tube included to protect cable from sharp edges of Attention All Add on cabinets must be grounded as well as the main cabinet...

Page 6: ...de It is not possible to make a mistake with the sockets all connectors are identical 1 5 Connection of control signals System could trigger up to 5 control signals from Battery module You could link...

Page 7: ...erface up to 82 bits Connectors X4 X1 Control panel 12 V GND D0 Data 0 D1 Data 1 1 7 Mains and Ground connection The key storage system has an internal input voltage of 24V with automatic switching to...

Page 8: ...so the system could recognize the key by its key fob Programming of the key fob key name and number is possible with the help of the program SecuriProx Studio supplied With the help of software you c...

Page 9: ...ress the Settings button on the battery charging module located inside the main unit from the right side On the tab IP settings it is necessary to set the IP address of the device the IP address of th...

Page 10: ...ettings tab This option allows you to test the cells for the keys presence to check up the solenoids operation Switch On the upper light and unlock the door lock On the Information tab you can see the...

Page 11: ...cess to the key storages without entering any additional information all you need is a card or a fingerprint When integrating with security alarm systems messages from the security alarm can be displa...

Page 12: ...t up and unlock the cell with your key In case you are allowed to take several keys to you will get a menu with only your key list You could check the status of keys In Out Blocked Wrong time to get Y...

Page 13: ...panel Time Date event In Out alarms The person name and phone number also available in case it is enabled by software Return You always could switch to return mode As soon as you choose key several ke...

Page 14: ...d Password You are allowed to return the key in any location The system will read the Key Fob information and recognize the key and remember it location The next day you will get this key from this lo...

Page 15: ...el With stainless steel insertion 2 mm IP protection IP 20 Dimension W H D 5 mod cabinet Dimension W H D 10 mod cabinet 430 mm x 742 mm x 132 mm 715 mm x 742 mm x 132 mm Control panel Dimension W H D...

Page 16: ...Available No door Available Memory User memory 50 000 more on request Event memory 50 000 more on request TFT Super bright 7 with capacity touch panel SmartKey Technology Dallas 1 wire Clamp Stainles...

Reviews: