KEY RK-2006SPGM Operation Manual Download Page 1

OPERATION MANUAL

RK-2006SPGM

Pellet fuel burner fitted boiler temperature controller.

Version 6315

version of the adapter

(MZK, MZM2, MZS, MZL)

Summary of Contents for RK-2006SPGM

Page 1: ...OPERATION MANUAL RK 2006SPGM Pellet fuel burner fitted boiler temperature controller Version 6315 version of the adapter MZK MZM2 MZS MZL...

Page 2: ......

Page 3: ...ring locations that shall be dry Figure 2 presents the electrical connection diagram CAUTION Before plugging in the controller first check if the wiring system is proper ly grounded and if the termina...

Page 4: ...of the device is to set the preset boiler temperature In this hands U need to turn the boiler thermostat knob 4 to set the correct value and confirm it with the OK button or press the knob CAUTION If...

Page 5: ...p work indicator 9 Burner capacity indicator the higher the capacity the brighter the flame 10 Cleaning device work indicator 11 Stoker work indicator 12 Feeder temperature 13 The operation indicator...

Page 6: ...water pumps operation but automatic ignition does not follow AUGER EXTINCT EMERGENCY SHUT DOWN Fuel ignition in auger channel The controller empties ignited fuel from the auger channel until temperatu...

Page 7: ...feeding rate is adjusted by the technician Pressing STOP button exceeding time limit for cleaning thermostat contacts opening or if water temperature in domestic water tank is obtained during operati...

Page 8: ...uence Afterburning EXTINCTION CLEANING Automatic burner cleaning occurs after time set limit by programmer In this mode controller starts cleaning system for preset time After this procedure controlle...

Page 9: ...y the technician Out of fuel alarm will be activated To turn on the controller again first refill fuel cancel the alarm with STOP button and begin setting up process by pressing START button Emergency...

Page 10: ...activates the pump absolutely CO The increase in water temperature in the boiler to the value programmed in parameter service TEMPERATURE BOILER OVERHEAT will turn off the fan heating pump switch the...

Page 11: ...the para meter will be backlit You can change the value of the selected parameter by turning the knob To confirm the change press the knob again and the controller will return to the list of paramete...

Page 12: ...and WOOD When the WOOD fuel is set you can burn the wood in the pellet boiler the controller operates at the wood fuel burning settings WOOD PELLET once the wood has been burned the controller switche...

Page 13: ...ivation of program for bacterial flora liquidation in domestic water tank When YES is selected it activates the process of heating the domestic water tank above 75 C When the required temperature is o...

Page 14: ...the system is fitted with flame temperature detector parameters change and viewing is unavailab le 1 13 The current furnace brightness determined by an optical detector this parameter displays the cu...

Page 15: ...mode CONSTANT once the thermostat is turned off the controller will switch into the MINIMUM CAPACITY mode instead of the POSTCOMBUSTION the mode saving the ignitor CONTINUOUS PLUS the burner is contin...

Page 16: ...want to change and press the knob a parameter is highlighted Turning the knob set the desired value and then press the knob Giving up mode changes and restore the previous value of the parameter by p...

Page 17: ...nsor 1 255 F 5 5 Flame failure detection delay 1s 255 F 5 6 Czas rozpalania paliwa Fuel ignition timea 1min 15min F 5 7 Ignition try count 1 10 F 5 8 Test the temperature of the fuel shortage 20 C 70...

Page 18: ...15200 10 4 MODBUS frame format 8N1 8E1 801 8N2 10 5 MODBUS access level NONE READOUT USER s SERVICE 10 6 Terminal access level NONE READOUT USER s SERVICE 10 7 Additional delay 0ms 9 9ms 13 x Circuit...

Page 19: ...e mode only if the adju stment process is stopped ie The regulator before entering the service mode was in STOP mode Selecting output testing allows the control knob to select the outputs on the displ...

Page 20: ...peed during boiler start setting After time expire the controller will increase fan speed up to the selected Max fan speed during boiler start setting 3 5 Fan speed during ignition this parameter desc...

Page 21: ...r purging setting was not selected 3 13 Fan speed during scavenge air purging this parameter specifies fan po wer during scavenge air purging This setting is unavailable if Fan scavenge air purging se...

Page 22: ...hat is fed to the burner during lighter operation The programmed setting specifies feeding time in percent in relation to the time of whole work cycle Selection of 0s setting will switch fuel feeding...

Page 23: ...ed with Stoker extra work time setting 4 8 Stoker work time this parameter specifies operation time of the stoker in who le work cycle This setting is unavailable if the stoker is switched off or in a...

Page 24: ...ctivates auger ignition alarm This parameter is unavailable when NO was selected in Auger ignition test setting 4 14 Duration of fuel feed rate enhancement period of time during which fuel feed rate i...

Page 25: ...tion procedure is started when the temperature drops or the brightness of the flame to the value of 0 5 5 Flame failure detection delay this parameter specifies how long after the launch procedures fo...

Page 26: ...ization firing This parameter is not available if the parameter STABILIZATION OF FIRING is set to NO 5 12 Smooth stabilization of ignition setting the parameter to YES will cause the stabilization of...

Page 27: ...eaning means burner shut down and start cleaning mechanism for the time set in parameter Cleaning mechanism work time After turning off the regulator output deducts the time set in parameter Cleaning...

Page 28: ...ode It specifies the time required for the mechanism retraction to the rest position after turning off the control output 6 4 Cleaning mechanism pause time this parameter is available only when the cl...

Page 29: ...AUTO or COMBI mode Specifies how many hours the burner can work without cleaning If the maximum time is reached the cleaning will run even if there was no required number of shut downs 7 x Central hea...

Page 30: ...ing will switch domestic water in the circuit purposed for control of the mixing pump In this case return water temperature sensor shall be connected instead of domestic water sensor and the mixing pu...

Page 31: ...e higher than the temperature required to heat the rooms This may result in extinction of the burner due to excee ding the hysteresis top of the boiler This parameter specifies how long is needed to s...

Page 32: ...r works in burner minimum power mode and boiler temperature increase follows by this programmed setting the controller will start burner extinction shut down 9 4 Burner power switching hysteresis when...

Page 33: ...mostat with contact output Contacts of the thermostat is signaled by the appearance of the ther mometer symbol in the index of the thermostat CAUTION The entrance of the room thermostat is active only...

Page 34: ...g external conditions we observe frequent overhea ting of the rooms increase the time constant During niedogrzewania value should be reduced 9 11 Burner off delay this parameter determines the time of...

Page 35: ...attributed to your controller and to avoid errors when a number of devices are switched to the bus Default value 1 10 3 MODBUS channel capacity selection of the RS 485 transmission speed Default valu...

Page 36: ...ERVICE changing all of the parameters is possible 10 6 Terminal access level defines to what extent access can be obtained through the remote terminal NO no access through the remote terminal READ OUT...

Page 37: ...ump AUTO Continuous pump operation 13 3 Weather control This function allows you to attach a weather control 13 4 Temperature set point circuit the temperature is maintained behind the mixing valve 13...

Page 38: ...ld ensure the system as well uses the main circuit as the central heating circulation when the 2 circuit operates 13 14 Use the main thermostat when the parameter is set to YES the standard boiler the...

Page 39: ...Power Supply 230 V 10 50 Hz Power consumption without fan and pump 2 VA Temperature measurement range KTY 81 210 39 109 C 1 C Temperature measurement range PT 1000 30 500 C 3 C Boiler temperature adj...

Page 40: ...40 Figure 2 RK 2006SPGM MZS Controller connection diagram...

Page 41: ...41 Figure 3 RK 2006SPGM MZL Controller connection diagram...

Page 42: ...42 Figure 4 RK 2006SPGM MZL Controller connection diagram...

Page 43: ...PN EN 61000 3 3 2011 EN 55022 2010 PN EN 55022 2011 Information on disposal This appliance is marked according to the European Directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE T...