1.16 Burner start up counter

– reading of this counter defines start number of the

ignition attempts.

1.17 Boiler on -

the parameter informs the user if the boiler is turned on and allows

him/her to turn it

on or off.

1.18 DHW heating on

– the parameter informs the user if the DHW heating is

turned on and allows him/her to turn it on or off.

1.19 Alarms cancellation.

The parameter enables the user to cancel the alarms recorded in the controller data

storage.

1.20 Burner mode.

INTERMITTENT

– turning off the thermostat will cause the controller to switch into

the POSTCOMBUSTION mode.

CONSTANT

– once the thermostat is turned off, the controller will switch into the

MINIMUM CAPACITY mode instead of the POSTCOMBUSTION (the mode saving

the ignitor).

1.21 SUMMER threshold temperature

– The transition temperature control in

SUMMER mode.

1.22 WINTER threshold temperature

– The transition temperature control in

WINTER mode.

Summary of Contents for RK-2006SPGM+MZS

Page 1: ...OPERATION MANUAL RK 2006SPGM Pellet fuel burner fitted boiler temperature controller Version 5701 MZS...

Page 2: ...Information on burner work 15 Alarms cancellation 15 Setting the parameters service mode 15 Table 3 Table service parameter 16 Language selection 18 Brightness saturation contrast of the display 18 S...

Page 3: ...locations that shall be dry Figure 2 presents the electrical con nection diagram For connection of stoker alarm indicator and ash removal system the additional module UM 1 shall be applied CAUTION Bef...

Page 4: ...of the device is to set the preset boiler temperature In this hands U need to turn the boiler thermostat knob 4 to set the correct value and confirm it with the OK button or press the knob CAUTION If...

Page 5: ...p work indicator 9 Burner capacity indicator the higher the capacity the brighter the flame 10 Cleaning device work indicator 11 Stoker work indicator 12 Feeder temperature 13 The operation indicator...

Page 6: ...water pumps operation but automatic ignition does not follow AUGER EXTINCT EMERGENCY SHUT DOWN Fuel ignition in auger channel The controller empties ignited fuel from the auger channel until temperatu...

Page 7: ...feeding rate is adjusted by the technician Pressing STOP button exceeding time limit for cleaning thermostat contacts opening or if water temperature in domestic water tank is obtained during operati...

Page 8: ...uence Afterburning EXTINCTION CLEANING Automatic burner cleaning occurs after time set limit by programmer In this mode controller starts cleaning system for preset time After this procedure controlle...

Page 9: ...y the technician Out of fuel alarm will be activated To turn on the controller again first refill fuel cancel the alarm with STOP button and begin setting up process by pressing START button Emergency...

Page 10: ...activates the pump absolutely CO The increase in water temperature in the boiler to the value programmed in parameter service TEMPERATURE BOILER OVERHEAT will turn off the fan heating pump switch the...

Page 11: ...the para meter will be backlit You can change the value of the selected parameter by turning the knob To confirm the change press the knob again and the controller will return to the list of paramete...

Page 12: ...he WOOD fuel is set you can burn the wood in the pellet boiler the controller operates at the wood fuel burning settings WOOD PELLET once the wood has been burned the controller switches to pellet bur...

Page 13: ...ivation of program for bacterial flora liquidation in domestic water tank When YES is selected it activates the process of heating the domestic water tank above 75 C When the required temperature is o...

Page 14: ...the system is fitted with flame temperature detector parameters change and viewing is unavailab le 1 13 The current furnace brightness determined by an optical detector this parameter displays the cu...

Page 15: ...ncellation The parameter enables the user to cancel the alarms recorded in the controller data storage 1 20 Burner mode INTERMITTENT turning off the thermostat will cause the controller to switch into...

Page 16: ...of parameters is possible by turning the multifunction knob possible to edit the parameter is highlighted After selecting the desired parameter press the OK button knob and enter the subgroups of a gi...

Page 17: ...r power 1 100 F 4 6 Fuel feed for min burner power 1 100 F 4 7 Stoker work mode see description 4 8 Stoker work time 1s 99s 4 9 Stoker pause time 1s 99s 4 10 Stoker extra work time 1s 99s 4 11 Stoker...

Page 18: ...r modulation factor 1 20 F 9 9 The operating mode of the thermostat NORMAL ADAPTIVE WEATHER F 9 10 The time constant adaptation 1min 99min F 9 11 Burner switch off delay 0min 99min F 9 12 Lowering the...

Page 19: ...roller it is possible to test various output devices This feature is available in service mode only if the adju stment process is stopped ie The regulator before entering the service mode was in STOP...

Page 20: ...peed during boiler start setting After time expire the controller will increase fan speed up to the selected Max fan speed during boiler start setting 3 5 Fan speed during ignition this parameter desc...

Page 21: ...accumulated gases 3 11 Fan scavenge air purging blow time this parameter specifies blow time 3 12 Fan scavenge air purging pause time this parameter specifies pause time during scavenge This setting i...

Page 22: ...hat is fed to the burner during lighter operation The programmed setting specifies feeding time in percent in relation to the time of whole work cycle Selection of 0s setting will switch fuel feeding...

Page 23: ...ed with Stoker extra work time setting 4 8 Stoker work time this parameter specifies operation time of the stoker in who le work cycle This setting is unavailable if the stoker is switched off or in a...

Page 24: ...emergency input is not used NO parameter shall be selected in Auger ignition test setting and contacts of X input shall be closed 4 13 Auger ignition temperature this parameter specifies auger tempera...

Page 25: ...tion procedure is started when the temperature drops or the brightness of the flame to the value of 0 5 5 Flame failure detection delay this parameter specifies how long after the launch procedures fo...

Page 26: ...arameter determines the maximum operating time of stabilization firing This parameter is not available if the parameter STABILIZATION OF FIRING is set to NO 5 12 Smooth stabilization of ignition setti...

Page 27: ...eaning means burner shut down and start cleaning mechanism for the time set in parameter Cleaning mechanism work time After turning off the regulator output deducts the time set in parameter Cleaning...

Page 28: ...ode It specifies the time required for the mechanism retraction to the rest position after turning off the control output 6 4 Cleaning mechanism pause time this parameter is available only when the cl...

Page 29: ...AUTO or COMBI mode Specifies how many hours the burner can work without cleaning If the maximum time is reached the cleaning will run even if there was no required number of shut downs 7 x Central hea...

Page 30: ...ing will switch domestic water in the circuit purposed for control of the mixing pump In this case return water temperature sensor shall be connected instead of domestic water sensor and the mixing pu...

Page 31: ...ation In this case after wor king for the hot water boiler water temperature may be higher than the temperature required to heat the rooms This may result in extinction of the burner due to excee ding...

Page 32: ...r works in burner minimum power mode and boiler temperature increase follows by this programmed setting the controller will start burner extinction shut down 9 4 Burner power switching hysteresis when...

Page 33: ...mostat with contact output Contacts of the thermostat is signaled by the appearance of the ther mometer symbol in the index of the thermostat CAUTION The entrance of the room thermostat is active only...

Page 34: ...g external conditions we observe frequent overhea ting of the rooms increase the time constant During niedogrzewania value should be reduced 9 11 Burner off delay this parameter determines the time of...

Page 35: ...attributed to your controller and to avoid errors when a number of devices are switched to the bus Default value 1 10 3 MODBUS channel capacity selection of the RS 485 transmission speed Default valu...

Page 36: ...ERVICE changing all of the parameters is possible 10 6 Terminal access level defines to what extent access can be obtained through the remote terminal NO no access through the remote terminal READ OUT...

Page 37: ...ycle in depending on the characteristics of the weather and room tempera ture AUTO the pump runs continuously The mixing valve keeps the temperature of the second circuit only depending on the charact...

Page 38: ...s the minimum boiler temperature that will be set on the boiler 13 7 The hysteresis circuit 2 parameter determines how much the temperature must fall the second circuit to control heat attached 13 8 T...

Page 39: ...h an external temperature sensor this parameter allows you to specify whether the sensor is installed In the absence of this parameter the sensor has to be turned off 14 2 Point 0 heating curve temper...

Page 40: ...he controller 8 Technical Data Power Supply 230 V 10 50 Hz Power consumption without fan and pump 2 VA Temperature measurement range KTY 81 210 39 109 C 1 C Temperature measurement range PT 1000 30 50...

Page 41: ...41 Figure 2 RK 2006SPGM Controller connection diagram...

Page 42: ...42...

Page 43: ...000 4 11 2005 U PN EN 60730 1 2002 A1 2006 U A12 2004 A13 2005 PN EN 60730 1 2005 A14 2006 PN EN 60730 2 9 2006 PN EN 61000 3 2 2006 U PN EN 61000 3 3 1997 A1 2005 A2 2006 IS1 2006 Information on disp...

Page 44: ...Manufacturer P W KEY 11 200 Bartoszyce ul Bohater w Warszawy 67 tel 89 763 50 50 fax 89 763 50 51 www pwkey pl e mail pwkey onet pl...