background image

�KeY

-

D

ISP 

The eBike Display 

User  Manual 

EMMO E-Wild X

Summary of Contents for EMMO E-Wild X

Page 1: ...KeY DISP The eBike Display User Manual EMMO E Wild X...

Page 2: ...Model KD718 Specifications 36V 48V Power Supply Rated working current 10mA The maximum working current 30mA Off state leakage current 1 A Operating temperature 20 60 Storage temperature 30 70 Appeara...

Page 3: ...ndication Assist level indication and selection Speed indication incl Real time speed Max speed and Ave speed Odometer and trip distance Push assistance control and indication Trip time indication Bac...

Page 4: ...wer When switching off the E bike system the leakage current is less than 1 A When parking the E bike for more than 5 minutes the E bike system switches off automatically Display Interface After switc...

Page 5: ...g unit The E bike system stops the power output immediately Push assistance Mode Push assistance function may only be used when pushing the E bike Be aware of danger of injury when the wheels of the E...

Page 6: ...ks at 5 to indicate the power highest After the power downshift reaches 0 press the button again the interface still shows 0 and blinks at 0 to indicate the power minimum The default value is level 1...

Page 7: ...tion The components of the E bike system are continuously and automatically monitored When an error is detected the respective error code is indicated in text indication area Here is the detail messag...

Page 8: ...terface All the Settings are operated on an E bike of no speed Wheel Diameter Settings Wheel represents wheel diameter settings To change basic settings press the or the button to increase or decrease...

Page 9: ...e until the desired value is displayed To store a changed setting press the i button to confirm Speed limit settings interface Backlight Brightness Settings Brightness represents backlight brightness...

Page 10: ...lt value is 41 2V To set battery power bar value press the or the button to increase or decrease the voltage values To store a changed setting and access the next bar voltage setting press the i butto...

Page 11: ...s 1 To store a changed setting press the i button to confirm Speed sensor setting Power Assistant Sensor Magnets Assistant Num represents the number of magnets on the PAS disk The settable range is 5...

Page 12: ...e desired mode and press the i button to confirm and access assist level ratio settings automatically Assist Level Mode Settings Interface Current limit Settings Current Limit represents controller ov...

Page 13: ...fault value can be customized To store a changed setting press the i button to confirm Sensitivity setting interface Slow start Slow start represents slow start up settings It is a time duration befor...

Page 14: ...d is by the percent To store a changed setting briefly press the i button to confirm SOC view setting interface Auto off Time Settings Dormancy represents display auto off time settings To change disp...

Page 15: ...store a changed setting briefly press the i button to confirm Mile and Kilometer Toggling Interface Password Settings Password means display power on password settings To access the power on password...

Page 16: ...d Successfully Then the display password is restoring the default code 1212 Password Enable Disable Settings Interface 2 Power on Password Reset From the last interface above press the or the button t...

Page 17: ...rface Factory settings Factory means restoring to default settings To reset to defaults press the or the button to choose YES or NO The default is NO To store a changed setting press the i button to c...

Page 18: ...Trip Reset represents trip distance clearance setting To clear trip distance press the button or the button to select Yes or No Yes represents clearing a single ride distance No represents not cleari...

Page 19: ...18 Exit Settings Exit means return back to home screen from setting pages If there is no operations in one minute the display will exit the settings state automatically...

Page 20: ...4 Wire of the display is broken 5 The fault or damage of the display is caused by the force majeure e g fire earthquake etc 6 Beyond Warranty period Connection Layout Standard connector wiring Displa...

Page 21: ...release or link the connector when battery is on Try to avoid hitting the display Don t modify system parameters to avoid parameter disorder Make the display repaired when error code appears This manu...