sa840_a30_inst_eng_400.doc
All specifications are subject to change. For latest info check on www.keyseven.com.
Having problems? Contact your dealer or visit our
homepage www.keyseven.com.
Select output format
Output format selection is done during power-up.
Connect wires a shown in below table, apply power, wait for buzzer acknowledge
and finish by disconnection power and the wires from below table.
Wire connection for programming
Format
no.
Output format
YELW
GREEN to
VIOLET to
WHITE
nothing
nothing
1
ABA (magstripe card)
Deafault selected
YELLOW
GREEN to
VIOLET to
nothing
WHITE
nothing
2
Wiegand
26-bit
YELLOW
GREEN to
VIOLET to
nothing
nothing
WHITE
3
RS232, 9600,N,8,1
Log function
YELLOW
GREEN to
VIOLET to
PINK
nothing
nothing
4
MI Wiegand
(26/8-bit)
Like til Motorola/Indala
YELLOWl
GREEN to
VIOLET to
PINK+WHT
nothing
nothing
5
UT
For use with Unitek, NOX Syst.
YELLOW
GREEN to
VIOLET to
PINK
WHITE
nothing
6
AVNG
For AlphaVisionNG/CP-508LCD
YELLOW
GREEN to
VIOLET to
PINK
nothing
WHITE
7
ATS Wiegand
YELLOW
GREEN to
VIOLET to
nothing
PINK
nothing
8
COOPER
For RS central panels
YELLOW
GREEN to
VIOLET to
WHITE
PINK
nothing
9
TAC Wiegand
For I/Net Seven
YELLOW
GREEN to
VIOLET to
nothing
WHITE
GREEN
10
Castle
(ver 4 eller nyere)
For CS2600/2700/2800
YELLOW
GREEN to
VIOLET to
nothing
PINK
WHITE
11
TAC ABA
For til I/Net Seven
Programming sequence:
1.
Select output format and connect wires acordingly
2.
If protocol 6 then the tamper circuit can be disabled connecting the
BROWN wire to ground now.
3.
Connect power
4.
Potocol 6/8/10 (Red LED flashes): Enter ID 1-8 or hold a random
prox up to the reader and wait for number of beeps according to ID
no. If this is not done then ID=1 (Cooper) or ID=8 (AVNG).
5.
Await number of beeps according to format no.
6.
Disconnet power and wires.
SA840-A30 is now programmet and ready for use. Programming is stored in
internal non-volatile memory of SA840-A30. Fascility code, if needed, can be
changed by use of TECH PC program. If programming sequence needs
changede then first follow below procedure for
Factory reset
.
Factory reset
1.
Disconnect power
2.
Connect PINK wire to ground (BLACK)
3.
Wait 5 seconds until red LED flashes
4.
Disconnect the PINK wire within next 5 seconds
5.
Disconnect power.
SA840 is now back in factory deafault state and a new protocol can be selected.
Mounting
SA840 mounts with only 2 screws on flat building surface
1
Mark the 4 drilling holes with the
drill guide and drill the holes
according to the wall material.
2
Fasten the nylon reflector.
3
Guide the cable trough the hole in
the wall and fasten screws loosely.
4
Connect SA840 wires appropriate and test tamper circuit with function 42 (
Sabotage
test). Tighten screws.
5
Clean key surface. Remove adhesive protection from front cover foil and place it
carefully on the SA850.
S
A
8
4
0
i
s
d
e
li
v
e
re
d
w
it
h
3
m
e
te
rs
o
f
fl
e
x
ib
le
1
4
-c
o
re
w
ir
e
:
Red
8-24V DC
Back
Ground. 0V
Green/White
-
Green/Brown
-
Yellow
CLS (ABA), Data 0 (Wiegand)
(open collector output)
Green
CCLK (ABA), Data 1 (Wiegand)
(open collector output)
Violet
CDAT (ABA)
(open collector output)
Blue
Tamper loop, wire 1
Blue/Pink
Tamper loop, wire 2
Gray/Pink
RS485 data, A (RS485)
Grey
RS485 data, B (RS485), TX (RS232)
White
LED indput
Pink
Buzzer input
Brown
Synchronizing. Only if two SA840’s are placed closer than 50cm to each other.
Technical specifications
Power supply
8V to 24V DC
Current consumption
typical 80mA
Tamper loop
isolated, max100mA, 25 ohm, 50V
Output formats
RS232 (9600,N,8,1) , RS485, Wiegand, ABA,
UT, AVNG, TAC
Wiegand facility code
Programmable, default 7
Network ID at delivery
1
Prox reading distance
up to 10 cm.
Prox type
125kHz, auto-tuning, EM4102 compatible
Dimensions (H-W-D)
0.59in-1.93in-0.59in (150mm-49mm-15mm)
Weight
10.2oz (286g)
Operating temperatures
-30
°
F to 150
°
F (-35
°
C to 65
°
C)
Operating humidity
0%-99%
Wire
10’ (3 m), 14-lead
SA840-A30
INSTALLATIONS MANUAL
Rev. 4.00
•
KEYPAD / PROX COMBO
•
MULTI PROTOKOL OUTPUT
•
SUITS MOST CONTROL PANELS
•
ALSO FOR OUTDOOR USE
•
SKAFOR approved in class 3
This manual applies for serial no. greater than 1xx20000
SA840-A30
emulates ABA mag. reader, Wiegand reader, RS232 and RS485
SA840-A30
has a programmable facility code for Wiegand interface
SA840-A30
interfaces directly to Alphatronics, Cooper, Castle and others
SA840-A30
is a molded weatherproof construction for outdoor use
SA840-A30
has an optical tamper security circuit
SA840-A30
LED’s and buzzer can be externally controlled
SA840-A30
has electrical isolated output for tamper/sabotage
SA840-A30
can be connected directly to PC or printer
SA840-A30
can be part of a SA850-series network
SA840-A30
uses standard 125KHz EM4100-based prox cords / tags
SA840-A30
is SKAFOR approved in class 3 (AIA 212.069)