background image

Start-up 

 

3062.72-01 Rev. A

 

S e i t e  

|

 

24

 

 

Definition of "far range":

 

 

The distance between the radio remote control and the motor 
control must be at least 1.5 meters. The distance between the 
radio remote control and the motor connection cable must be 
at least 0.5 meters. 

 

 

Step 1: Activate learning mode: 

I

mportant:  After  every  disconnection  of  the  power  supply  the 

learning mode can be activated within 30 min. 

 

 

Switch the power supply off and on again, e.g. fuse OFF - ON. If 
the  motor  is  connected  correctly,  it  makes  a  short  UP  and 
DOWN movement. 

 

You hear 1x "Klack - Klack"  

 

 

 

 

In the close range, press UP or DOWN key and hold for approx. 
3 seconds until the motor confirms. 

You hear 1x "Klack - Klack"  

 

 

 

 

If now no action is taken within 60 seconds, the learning mode is deactivated! The motor 
returns to normal operation mode. You will hear 3 x "Klack - Klack". 
 

 

Summary of Contents for Drive System 3062

Page 1: ...Rev A Assembly instructions Drive System 3062 3062 00 V01XXX 3062 00 XXXX Original assembly instructions 3062 72 01 for partly completed machines According to machinery directive 2006 42 EG Attachment...

Page 2: ...de 2022 B Ketterer S hne GmbH Co KG 78120 Furtwangen All rights reserved in particular the right of reproduction distribution and translation No part of this manual may be reproduced in any form or s...

Page 3: ...2 00 V01XXX 10 3 3 Dimension 11 3 3 1 Dimension 3062 00 0010 11 3 3 2 Dimension 3062 00 0011 12 3 3 3 Dimension 3062 00 V01XXX 13 3 4 Technical data operating conditions 14 4 Packing Transport Unpacki...

Page 4: ...nstructions The user must check this before use and observe the differences if necessary 1 2 Scope These instructions are valid for the incomplete machine with article number 3062 00 V01XXX and 3062 0...

Page 5: ...to hazards Hot surface warning This warning sign stands in front of activities where there is a hazard from hot surfaces which can lead to burns Warning of electric shock This warning sign stands in f...

Page 6: ...ituation which if not avoided will result in death or serious irreversible injury DANGER Indicates a hazardous situation which if not avoided could result in death or serious irreversible injury WARNI...

Page 7: ...ific hazard The warning is structured as follows SIGNAL WORD Nature of the hazard and its source Possible Consequence s of disregard Action s to avoid the hazard 1 4 2 Structure of the embedded warnin...

Page 8: ...le in a readable condition 2 1 Personnel Qualification und obligations Information All activities on and with the drive system must only be performed by authorized personnel The authorized personnel m...

Page 9: ...cognizable safety defects immediately to their superiors During start up and operation the operator must ensure that there are no persons in the danger zone The danger zone depends on the function and...

Page 10: ...In emergency situations this version cannot be operated manually The integrator or operator of the application must provide sufficient safety in emergency situations The spindle system must be individ...

Page 11: ...motor activity Assembly Start up Operation Electrical voltage residual energy Residual electrical energy may remain in lines electrical components equipment and devices when the drive system is switc...

Page 12: ...mbrellas The system can be integrated into the mast tube of the umbrella and is therefore not visible from the outside The emergency hand crank allows to close the umbrella manually in emergency situa...

Page 13: ...tor with integrated control and radio module connection cable 230V with open wires 1 1 channel radio remote control 1 Emergency hand crank with integrated ejection mechanism 1 Spindle unit SG25x4 RH i...

Page 14: ...Product description 3062 72 01 Rev A S e i t e 11 3 3 Dimension The dimensions depend on the version 3 3 1 Dimension 3062 00 0010 Figure 3 1 Dimensions of the drive system 3062 00 0010...

Page 15: ...Product description 3062 72 01 Rev A S e i t e 12 3 3 2 Dimension 3062 00 0011 Figure 3 2 Dimensions of the drive system 3062 00 0011...

Page 16: ...Rev A S e i t e 13 3 3 3 Dimension 3062 00 V01XXX Figure 3 3 Dimensions of the drive system 3062 00 V01XXX Customer specific adaptation for 3062 00 V01XXX Dimension of the gear housing can be realised...

Page 17: ...o remote control 434 MHz Nominal torque peak torque 5 Nm 7 Nm short term idle speed 134 U min Nominal speed 120 U min 5 Nm Operating mode S2 4 min Operating ambient temperature humidity T 10 C 60 C H...

Page 18: ...must be protected adequately from moisture e g rainwater Observe the temperature ranges during the entire transport These must not be exceeded or underrun These are 15 C to 70 C 4 2 Unpacking Make su...

Page 19: ...l protective equipment depending on the environmental conditions Preparatory activities Inspect the drive system for external mechanical damage before starting the assembly Remove all packaging compon...

Page 20: ...unting position in the application and must be selected by taking the specified thread length into account The screw in depth should be at least 8 mm for M6 screws Fasten the spindle nut to the screw...

Page 21: ...apply excessive forces to any parts of the drive system during mechanical assembly Do not use a hammer to push into the application Do not drop the drive system The device must be mounted as described...

Page 22: ...ween the wires a short circuit may result This can result in death or serious injury All plug connections must be protected against extended immersion in water but at least IP68 Preparatory activities...

Page 23: ...and plug or other means of disconnection from the mains which has a contact opening width in each pole corresponding to the conditions of overvoltage category III for full disconnection such a disconn...

Page 24: ...Assembly 3062 72 01 Rev A S e i t e 21 5 4 1 Circuit diagram Figure 5 4 Circuit diagram...

Page 25: ...f persons and or objects are in the danger zone of the application serious injuries and or material damage may occur During initial start up only activate the drive system if there are no persons or o...

Page 26: ...ional Before start up have the electrical equipment checked by a qualified electrician in accordance with the standards and regulations applicable in the country of use Check for correct mechanical as...

Page 27: ...very disconnection of the power supply the learning mode can be activated within 30 min Switch the power supply off and on again e g fuse OFF ON If the motor is connected correctly it makes a short UP...

Page 28: ...ep 1 In the close range press the UP or DOWN key and hold it down for approx 5 seconds The motor responds immediately You hear 1 x Klack Klack Press and hold the button until the motor confirms the de...

Page 29: ...tion If persons and objects are in the danger zone of the application considerable injuries and or material damage may occur Activate the motor only when you are near the application to be able to int...

Page 30: ...d or material damage The Ketterer emergency crank handle has an integrated ejector mechanism to prevent it from getting stuck This ejector mechanism must not be modified Remove the emergency hand cran...

Page 31: ...using the emergency hand crank Make sure that no controlling can happen via the radio remote control during operation with emergency hand crank Store the emergency hand crank in a safe place that is...

Page 32: ...refore observe the following safety instructions The application must always be observed when wind is a threat The operator must check the wind strength before operating the drive system In the event...

Page 33: ...sal The disposal of the drive system with its mechanical and electrical components as well as all operating fluids is based on the local disposal regulations and the environmental protection laws in t...

Page 34: ...e of approx 15 minutes The motor no longer runs automatically The wind sensor has triggered a blocking time Try again after the wind lock time of 10 minutes has elapsed The radio remote control was ac...

Page 35: ......

Reviews: