Operating Manual
Thank you for purchasing this product.
Please read the operating manual carefully and use this product properly.
Biomass Fuel Moisture Tester
HI-700
Page 1: ...Operating Manual Thank you for purchasing this product Please read the operating manual carefully and use this product properly Biomass Fuel Moisture Tester HI 700...
Page 2: ......
Page 3: ...5 2 Product number viewing 8 5 3 Product number selection 9 6 Sample Extraction and Measurement 10 6 1 Manual hopper 10 6 2 How to extract a sample 10 6 3 Measurement 11 7 Other functions 14 7 1 Disp...
Page 4: ...fer to the Product List attached for measurable biomass fuel versions Because the calibration curves of products on the Product List have been already stored the measurement of a sample on the list ca...
Page 5: ...less versus drying method all products with moisture content of less than 20 Correction function Mass By integrated weighing scale Temperature By thermistor Other functions Average auto power off Dis...
Page 6: ...Front Accessories Measuring section sample inlet Battery cover Keyboard Display Inner cylinder Funnel Manual hopper Sample cup Product list Operating manual Brush Batteries 1 5V R6 or AA size x4 HI 70...
Page 7: ...d MEA key Measurement POWER key Power On Off Moisture value Battery level icon Product name Version No Product number Sample in Sample out icon Number of measuring SELECT key Selection of products AVG...
Page 8: ...the ambient temperature around the measuring unit and automatically performs temperature correction If the displayed measured value blinks warning indication see 8 Error Display on page 16 5 1 Battery...
Page 9: ...played in the following order 01 02 03 04 2 For example to change to 04 WP when 01 PKSD is displayed 3 Press the key 3 times to adjust the product number to 03 4 Now 04 WP is selected Note The product...
Page 10: ...o extract a sample 1 Mount the funnel on the manual hopper and load a sample into the funnel to one third of the funnel depth 2 Remove the funnel to eliminate surplus sample and to level off the sampl...
Page 11: ...nnot be performed and the decimal point blinking may not stop 2 After the sample in icon starts to blink load the sample from the manual hopper into the center of the measuring unit as shown in the dr...
Page 12: ...displayed measurement precision is not as good as lower moisture content samples Note 2 When the moisture content is below the measurement range Lo is displayed and when the moisture content is above...
Page 13: ...and starts the zero adjustment Note 2 The high moisture sample remaining may cause the measurement error due to the deterioration of the electrode Discharge immediately and clean with the included bru...
Page 14: ...surement count starts from 1st 7 2 Auto power off If no measurement or operation is performed for 3 minutes with the power on the power is automatically turned off to avoid battery drain A buzzer soun...
Page 15: ...Use the tester in the operating temperature of 0 to 40 C 014 Main unit temperature is too low under 10 C 015 Main unit board temperature is too high over 60 C 016 Main unit board temperature is too lo...
Page 16: ...erating temperature range 0 40 C The temperature difference between the sample and main unit board is 10 C or more Note1 The measurement value displayed with a warning may have a large error Use withi...
Page 17: ...h may lead to breakdown 3 The protrusion inside the measuring unit is the temperature sensor and therefore be careful not to break it 4 When the inner portion of the measuring unit becomes dirty use a...
Page 18: ......
Page 19: ......
Page 20: ...displayed on this manual may differ from the actual ones however operations and functions are not affected All efforts have been made to ensure the contents of this manual are accurate However if you...