KERN CDS 100K0.5 Operating Manual Download Page 1

 

 

KERN & Sohn GmbH

 

Ziegelei 1 
D-72336  Balingen 
email: [email protected] 

Phone:  +49-[0]7433- 9933-0 
Fax: +49-[0]7433-9933-149 
Internet: www.kern-sohn.com 

 
 
 

Operating Manual 
Counting balances 

 
 

KERN CKE/CDS 

Version 2.6 
01/2015 
GB

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

CKE-BA-e-1526 

Summary of Contents for CDS 100K0.5

Page 1: ...H Ziegelei 1 D 72336 Balingen email info kern sohn com Phone 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com Operating Manual Counting balances KERN CKE CDS Version 2 6 01 2015 GB C...

Page 2: ...lacing 11 6 3 Mains connection 11 6 4 Battery operation CKE 12 6 5 Connection of peripheral devices 12 6 6 Initial Commissioning 12 6 7 Adjustment 13 6 8 Adjusting see chapter 7 2 1 13 6 9 Verificatio...

Page 3: ...tare key and press the ON OFF key Let go of the tare key Using the automatic reference optimization OPT the counting accuracy is automatically increased when applying up to 100 items Factory settings...

Page 4: ...3 0 3 6 kg 2 4 5 6 kg Recommended adjustment weight F1 not added 300 g 2 kg 2 kg 1 kg 5 kg Appropriate for verification max 80 rel non condensing Stabilization time typical 3 sec Allowable ambient te...

Page 5: ...7 8 kg 5 10 15 16 kg 5 10 15 16 kg Recommended adjustment weight F1 not added 5 kg 2 kg 10 kg 5 kg 10 kg 5 kg Appropriate for verification max 80 rel non condensing Stabilization time typical 3 sec A...

Page 6: ...kg 20 30 50 60 kg 20 30 50 60 kg Recommended adjustment weight F1 not added 20 kg 10 kg 50 kg 50 kg Appropriate for verification max 80 rel non condensing Stabilization time typical 3 sec Allowable a...

Page 7: ...t point kg 1 2 4 2 5 10 15 2 5 10 15 16 10 15 20 30 10 15 20 30 Recommended adjustment weight F1 not added 2 kg 2 kg 10 kg 5 kg 10 kg 5 kg 20 kg 10 kg 20 kg 10 kg Appropriate for verification max 80 r...

Page 8: ...36 20 30 50 60 20 50 100 Recommended adjustment weight F1 not added 20 kg 10 kg 50 kg 50 kg 50 kg Appropriate for verification max 80 rel non condensing Stabilization time typical 3 sec Allowable amb...

Page 9: ...in explosive environment The serial version is not explosion protected The structure of the balance may not be modified This may lead to incorrect weighing results safety related faults and destructio...

Page 10: ...ing immediately and the appliance itself when unpacking for possible visible damage In case of visible damage have the damage verified by the messenger s signature Do not alter goods or packaging and...

Page 11: ...n of air humidity on the appliance may occur if a cold appliance is taken to a considerably warmer environment In this case acclimatize the disconnected appliance for ca 2 hours at room temperature Av...

Page 12: ...tical value for operational safety this will be indicated in the display with the BATT LOW information 6 5 Connection of peripheral devices Before connecting or disconnecting of additional devices pri...

Page 13: ...warming up time of ca 15 minutes is recommended for stabilization 6 9 Verification General introduction According to EU directive 90 384 EEC balances must be officially verified if they are used as f...

Page 14: ...nce using 10 parts Generate reference using 20 parts In mode menu YES function Switchover pcs g In menu Mode function Print out weighing result Display icon Significance OVERLOAD Overload Weighing ran...

Page 15: ...7 2 Operation 7 2 1 Adjusting 7 2 2 Speed 7 2 3 Auto Off CKE CDS BA e 1526 15...

Page 16: ...CKE CDS BA e 1526 16...

Page 17: ...o select the menu point Backlight auto and confirm by pressing the YES button The background illumination will be switched off automatically 10 sec after having reached a stable weighing value 7 2 5 S...

Page 18: ...ground Baud rate The MODE key is used to set the Baud rate used for the transfer of measured values In the following example the baud rate is set to 4800 baud Setting Baud rate KERN CKE Display 1 Swit...

Page 19: ...f When AUTOPRINT PC is active the current weighing values will be sent continuously via the RS 232 data interface Data output and remote control commands Remote control commands transferred as ASCII c...

Page 20: ...e to their size or shape can be weighed with the help of the underfloor weighing facility Proceed as follows Switch off balance Turn over the balance and in doing so take care that the weighing plate...

Page 21: ...case of an error in the program process briefly turn off the balance and disconnect from power supply The weighing process must then be restarted from the beginning Help Fault Possible cause The displ...

Page 22: ...duit auquel se rapporte la pr sente d claration est conforme aux normes cit es ci apr s I Dichiarazione di conformit Dichiariamo con ci che il prodotto al quale la presente dichiarazione si riferisce...