1.5
Description of the modules
1.5.1
CPU module
1.5.1.1
Mechanical description
The CPU module is composed of four main mechanical parts:
A “three-sides” flange including:
o
the connectors and interfaces placement
o
venting of internal boards through many holes
A rear plate with fixing points for screwing on the blind threaded standoffs
Two radiators used as right and left side flanges
Figure 17: Mechanical description of the CPU module
The main mechanical characteristics of the CPU module are detailed hereafter:
Description
Specification
Radiators material
Aluminum
Other flanges material
Galvanized Steel
Dimensions
156 mm x 88 mm x 38 mm
Weight
500 g
Rear plate
Fixing points
for screwing
Radiators
« 3 sides »
flange
Holes
Back panel